Literature DB >> 22285093

Left ventricular dyssynchrony using three-dimensional speckle-tracking imaging as a determinant of torsional mechanics in patients with idiopathic dilated cardiomyopathy.

Kensuke Matsumoto1, Hidekazu Tanaka, Kazuhiro Tatsumi, Tatsuya Miyoshi, Mana Hiraishi, Akihiro Kaneko, Takayuki Tsuji, Keiko Ryo, Yuko Fukuda, Akihiro Yoshida, Hiroya Kawai, Ken-Ichi Hirata.   

Abstract

The aim of this study was to use 3-dimensional (3D) speckle-tracking echocardiography to test the hypothesis that left ventricular (LV) dyssynchrony may negatively affect LV torsional mechanics in patients with idiopathic dilated cardiomyopathy (IDC) and that LV torsion may improve after cardiac resynchronization therapy. This study included 65 subjects; 20 with IDC with ejection fractions ≤35% and wide QRS complexes (≥120 ms), 20 with IDC with ejection fractions ≤35% and narrow QRS complexes (<120 ms), and 25 controls. LV dyssynchrony index was determined as the SD of time to peak 3D speckle-tracking radial strain and regional heterogeneity of LV rotation (rotational dispersion index) as the SD of 3D speckle-tracking time to peak rotation. All rotational indexes were significantly impaired in patients with IDC, while LV torsion in patients with IDC with wide QRS complexes was significantly smaller than that in patients with IDC with narrow QRS complexes and controls. Conversely, LV dyssynchrony index (127.3 ± 24.0 ms [p <0.01 vs controls and vs patients with narrow QRS complexes] vs 88.8 ± 22.5 ms [p <0.01 versus controls] vs 30.9 ± 10.0 ms) and rotational dispersion index (115.1 ± 27.5 ms [p <0.01 vs controls and vs patients with narrow QRS complexes] vs 96.0 ± 23.4 ms [p <0.01 versus controls] vs 45.0 ± 13.7 ms) were significantly higher in patients with IDC with wide QRS complexes. Multivariate analysis showed that the LV ejection fraction (β = 0.688, p <0.001) and rotational dispersion index (β = -0.249, p <0.01) were independent determinants of LV torsion. Moreover, LV torsion in patients with IDC with wide QRS complexes improved after cardiac resynchronization therapy (p <0.05), along with reductions in LV dyssynchrony and rotational dispersion indexes. In conclusion, these findings obtained with a novel 3D speckle-tracking system feature a novel aspect of LV torsional mechanics and demonstrate its association with LV dyssynchrony.
Copyright © 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22285093     DOI: 10.1016/j.amjcard.2011.11.059

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  10 in total

Review 1.  Current role of echocardiography in cardiac resynchronization therapy.

Authors:  Donato Mele; Matteo Bertini; Michele Malagù; Marianna Nardozza; Roberto Ferrari
Journal:  Heart Fail Rev       Date:  2017-11       Impact factor: 4.214

2.  Further deterioration of LV ejection fraction and mechanical synchrony during RV apical pacing in patients with heart failure and LBBB.

Authors:  Daniel R Ludwig; Hidekazu Tanaka; Mati Friehling; John Gorcsan; David Schwartzman
Journal:  J Cardiovasc Transl Res       Date:  2013-03-19       Impact factor: 4.132

Review 3.  The role of 3D wall motion tracking in heart failure.

Authors:  Yiu-fai Cheung
Journal:  Nat Rev Cardiol       Date:  2012-09-04       Impact factor: 32.419

Review 4.  How His bundle pacing prevents and reverses heart failure induced by right ventricular pacing.

Authors:  Alfred Stanley; Constantine Athanasuleas; Gerald Buckberg
Journal:  Heart Fail Rev       Date:  2021-11       Impact factor: 4.214

Review 5.  Role of Speckle Tracking Echocardiography in Dilated Cardiomyopathy: A Review.

Authors:  Ghulam Murtaza; Hafeez Ul Hasan Virk; Muhammad Khalid; Zia Rahman; Puja Sitwala; Jeffrey Schoondyke; Kais Al-Balbissi
Journal:  Cureus       Date:  2017-06-20

6.  Evaluation of left ventricular strain in patients with dilated cardiomyopathy.

Authors:  Yaohan Yu; Sisi Yu; Xuepei Tang; Haibo Ren; Shuhao Li; Qian Zou; Fakui Xiong; Tian Zheng; Lianggeng Gong
Journal:  J Int Med Res       Date:  2017-06-06       Impact factor: 1.671

7.  Reproducibility of Left Ventricular Dyssynchrony Indices by Three-Dimensional Speckle-Tracking Echocardiography: The Impact of Sub-optimal Image Quality.

Authors:  Lamia Al Saikhan; Chloe Park; Alun D Hughes
Journal:  Front Cardiovasc Med       Date:  2019-10-10

Review 8.  Echocardiographic tissue imaging evaluation of myocardial characteristics and function in cardiomyopathies.

Authors:  Takahide Ito; Michihiro Suwa
Journal:  Heart Fail Rev       Date:  2021-07       Impact factor: 4.214

9.  Mechanical effects of left ventricular midwall fibrosis in non-ischemic cardiomyopathy.

Authors:  Robin J Taylor; Fraz Umar; Erica L S Lin; Amar Ahmed; William E Moody; Wojciech Mazur; Berthold Stegemann; Jonathan N Townend; Richard P Steeds; Francisco Leyva
Journal:  J Cardiovasc Magn Reson       Date:  2016-01-05       Impact factor: 5.364

Review 10.  Cardiac Resynchronization Therapy in Non-Ischemic Cardiomyopathy: Role of Multimodality Imaging.

Authors:  Cristian Stătescu; Carina Ureche; Ștefana Enachi; Rodica Radu; Radu A Sascău
Journal:  Diagnostics (Basel)       Date:  2021-03-30
  10 in total