Literature DB >> 22284990

Comparison of different camera calibration approaches for underwater applications.

Amanda Piaia Silvatti1, Fabio Augusto Salve Dias, Pietro Cerveri, Ricardo M L Barros.   

Abstract

The purpose of this study was to compare three camera calibration approaches applied to underwater applications: (1) static control points with nonlinear DLT; (2) moving wand with nonlinear camera model and bundle adjustment; (3) moving plate with nonlinear camera model. The DVideo kinematic analysis system was used for underwater data acquisition. The system consisted of two gen-locked Basler cameras working at 100 Hz, with wide angle lenses that were enclosed in housings. The accuracy of the methods was compared in a dynamic rigid bar test (acquisition volume-4.5×1×1.5 m(3)). The mean absolute errors were 6.19 mm for the nonlinear DLT, 1.16 mm for the wand calibration, 1.20 mm for the 2D plate calibration using 8 control points and 0.73 mm for the 2D plane calibration using 16 control points. The results of the wand and 2D plate camera calibration methods were less associated to the rigid body position in the working volume and provided better accuracy than the nonlinear DLT. Wand and 2D plate camera calibration methods presented similar and highly accurate results, being alternatives for underwater 3D motion analysis. Copyright Â
© 2012 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22284990     DOI: 10.1016/j.jbiomech.2012.01.004

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  8 in total

1.  Reconstruction Accuracy Assessment of Surface and Underwater 3D Motion Analysis: A New Approach.

Authors:  Kelly de Jesus; Karla de Jesus; Pedro Figueiredo; João Paulo Vilas-Boas; Ricardo Jorge Fernandes; Leandro José Machado
Journal:  Comput Math Methods Med       Date:  2015-06-14       Impact factor: 2.238

2.  Normative 3D opto-electronic stereo-photogrammetric posture and spine morphology data in young healthy adult population.

Authors:  Moreno D'Amico; Edyta Kinel; Piero Roncoletta
Journal:  PLoS One       Date:  2017-06-22       Impact factor: 3.240

Review 3.  Behavioral Dynamics in Swimming: The Appropriate Use of Inertial Measurement Units.

Authors:  Brice Guignard; Annie Rouard; Didier Chollet; Ludovic Seifert
Journal:  Front Psychol       Date:  2017-03-14

4.  Normative 3D opto-electronic stereo-photogrammetric sagittal alignment parameters in a young healthy adult population.

Authors:  Edyta Kinel; Moreno D'Amico; Piero Roncoletta
Journal:  PLoS One       Date:  2018-09-07       Impact factor: 3.240

5.  Reliability of Measuring Leg Segments and Joint Angles Using Smartphones during Aquatic Exercise.

Authors:  Dae Hee Lee; Seulki Han
Journal:  Healthc Inform Res       Date:  2022-01-31

6.  Gait Kinematic Analysis in Water Using Wearable Inertial Magnetic Sensors.

Authors:  Silvia Fantozzi; Andrea Giovanardi; Davide Borra; Giorgio Gatta
Journal:  PLoS One       Date:  2015-09-14       Impact factor: 3.240

7.  Action Sport Cameras as an Instrument to Perform a 3D Underwater Motion Analysis.

Authors:  Gustavo R D Bernardina; Pietro Cerveri; Ricardo M L Barros; João C B Marins; Amanda P Silvatti
Journal:  PLoS One       Date:  2016-08-11       Impact factor: 3.240

8.  Moving system with action sport cameras: 3D kinematics of the walking and running in a large volume.

Authors:  Gustavo R D Bernardina; Tony Monnet; Pietro Cerveri; Amanda P Silvatti
Journal:  PLoS One       Date:  2019-11-12       Impact factor: 3.240

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.