Literature DB >> 22284886

Evaluation of low-cost disposable polymeric materials for sorptive extraction of organic pollutants in water samples.

Ailette Prieto1, Rosario Rodil, José Benito Quintana, Isaac Rodríguez, Rafael Cela, Monika Möder.   

Abstract

The capabilities of four commercially available and low cost polymeric materials for the extraction of polar and non-polar contaminants (logK(ow)=-0.07-6.88, from caffeine to octocrylene, respectively) from water samples was compared. Tested sorbents were polyethersulphone, polypropylene and Kevlar, compared to polydimethylsiloxane as reference material. Parameters that affect the extraction process such as pH and ionic strength of the sample, extraction time and desorption conditions were thoroughly investigated. A set of experimental partition coefficients (K(pw)), at two different experimental conditions, was estimated for the best suited materials and compared with the theoretical octanol-water (K(ow)) partition coefficients of the analytes. Polyethersulphone displayed the largest extraction yields for both polar and non-polar analytes, with higher K(pw) and lower matrix effects than polydimethylsiloxane and polypropylene. Thus, a sorptive microextraction method, followed by large volume injection (LVI) gas chromatography-tandem mass spectrometry (GC-MS/MS), was proposed using the former sorbent (2 mg) for the simultaneous determination of model compounds in water samples. Good linearity (>0.99) was obtained for most of the analytes, except in the case of 4-nonylphenol (0.9466). Precision (n=4) at 50 and 500 ng L(-1) levels was in the 2-24% and limits of detection (LODs) were in the 0.6-25 ng L(-1) range for all the analytes studied.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22284886     DOI: 10.1016/j.aca.2011.12.023

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  3 in total

1.  Combination of different chromatographic and sampling modes for high-resolution mass spectrometric screening of organic microcontaminants in water.

Authors:  Verónica Castro; José Benito Quintana; Inmaculada Carpinteiro; Julio Cobas; Nieves Carro; Rafael Cela; Rosario Rodil
Journal:  Anal Bioanal Chem       Date:  2021-02-24       Impact factor: 4.142

2.  Assessment of commercially available polymeric materials for sorptive microextraction of priority and emerging nonpolar organic pollutants in environmental water samples.

Authors:  Laura Blanco-Zubiaguirre; Alejandra Delgado; Oihana Ros; Oscar Posada-Ureta; Asier Vallejo; Ailette Prieto; Maitane Olivares; Nestor Etxebarria
Journal:  Environ Sci Pollut Res Int       Date:  2014-01-15       Impact factor: 4.223

3.  Development and application of an in-house library and workflow for gas chromatography-electron ionization-accurate-mass/high-resolution mass spectrometry screening of environmental samples.

Authors:  Verónica Castro; José Benito Quintana; Javier López-Vázquez; Nieves Carro; Julio Cobas; Denis Bilbao; Rafael Cela; Rosario Rodil
Journal:  Anal Bioanal Chem       Date:  2021-12-04       Impact factor: 4.478

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.