Literature DB >> 22283116

Electrochemical surface plasmon resonance measurement based on gold nanohole array fabricated by nanoimprinting technique.

Kohei Nakamoto1, Ryoji Kurita, Osamu Niwa.   

Abstract

In this paper, we describe our development of an electrochemical surface plasmon resonance (EC-SPR) measurement device based on a bottom-filled gold nanohole array. The polymer based gold nanohole array was fabricated with a UV nanoimprint technique and electron beam gold deposition. Direct reflection mode measurement was used to monitor the SPR dip in the reflection spectra. A cyclic voltammogram was also operated by using the standard three electrodes containing working electrode having a gold nanohole array and counter and reference electrodes. The gold nanohole array was modified with an osmium-poly(vinylpyridine)-wired horseradish peroxidase (Os-gel-HRP) film, and its redox state induced by the change in potential was monitored simultaneously. The redox state of the local film was obtained simply by scanning the sample substrate stage. The substrate modified with Os-gel-HRP film was incorporated in a microfluidic chip, and then the hydrogen peroxide was determined in terms of the redox change in the Os complex mediator from the slope of the SPR dip shift. The linear relation of hydrogen peroxide from 10 to 250 μM was successfully monitored, and a high conversion efficiency was realized.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22283116     DOI: 10.1021/ac203160r

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  4 in total

Review 1.  Nanohole array plasmonic biosensors: Emerging point-of-care applications.

Authors:  Alisha Prasad; Junseo Choi; Zheng Jia; Sunggook Park; Manas Ranjan Gartia
Journal:  Biosens Bioelectron       Date:  2019-01-24       Impact factor: 10.618

2.  Ultrasmooth metallic films with buried nanostructures for backside reflection-mode plasmonic biosensing.

Authors:  Nathan C Lindquist; Timothy W Johnson; Jincy Jose; Lauren M Otto; Sang-Hyun Oh
Journal:  Ann Phys       Date:  2012-11

3.  Promises and Challenges of Nanoplasmonic Devices for Refractometric Biosensing.

Authors:  Andreas B Dahlin; Nathan J Wittenberg; Fredrik Höök; Sang-Hyun Oh
Journal:  Nanophotonics       Date:  2013-01       Impact factor: 8.449

4.  Quantification of a cardiac biomarker in human serum using extraordinary optical transmission (EOT).

Authors:  Tao Ding; Minghui Hong; A Mark Richards; Ten It Wong; Xiaodong Zhou; Chester Lee Drum
Journal:  PLoS One       Date:  2015-03-16       Impact factor: 3.240

  4 in total