Literature DB >> 22281661

Quantification of holmium-166 loaded microspheres: estimating high local concentrations using a conventional multiple gradient echo sequence with S₀-fitting.

Gerrit H van de Maat1, Peter R Seevinck, Clemens Bos, Chris J G Bakker.   

Abstract

PURPOSE: To provide a best estimate of the R 2* value and hence of the local concentration of highly paramagnetic holmium-166 loaded microspheres (HoMS) in voxels for which R 2* cannot be characterized by conventional fitting of multigradient echo (MGE) data because of fast signal decay due to high local concentrations.
MATERIALS AND METHODS: A postprocessing method, S(0)-fitting, was implemented in a conventional R 2* fitting method that is used for quantification of HoMS. S(0)-fitting incorporates the estimated initial amplitude of the free induction decay (FID) curve, S(0), of neighboring voxels into the fitting procedure for voxels for which the conventional algorithm failed. The method was applied to HoMS in vitro and ex vivo in a rabbit liver. The performance of the S(0)-fitting method was evaluated by comparing results qualitatively and quantitatively with results obtained with quantitative ultrashort TE imaging (qUTE).
RESULTS: Applying S(0)-fitting provided a best estimate for R 2* up to a value of about 2300 s(-1) compared with a maximum value of about 1000 s(-1) that could be characterized using conventional fitting. A good agreement was observed both qualitatively and quantitatively for in vitro experiments as well as for ex vivo rabbit liver experiments between results obtained with S(0)-fitting and results obtained with qUTE imaging.
CONCLUSION: S(0)-fitting is a postprocessing method that can provide a best estimate of high R 2* values that cannot be characterized by conventional relaxometry. The method can be applied to conventional MGE datasets and was shown to be beneficial for quantification of high local concentrations of holmium-loaded microspheres.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22281661     DOI: 10.1002/jmri.23593

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  2 in total

Review 1.  Transarterial Radioembolization (TARE) Agents beyond 90Y-Microspheres.

Authors:  C Bouvry; X Palard; J Edeline; V Ardisson; P Loyer; E Garin; N Lepareur
Journal:  Biomed Res Int       Date:  2018-12-31       Impact factor: 3.246

Review 2.  To 1000 Gy and back again: a systematic review on dose-response evaluation in selective internal radiation therapy for primary and secondary liver cancer.

Authors:  Nienke J M Klaassen; Lovisa E L Westlund Gotby; Joey Roosen; Christiaan G Overduin; Marcel Verheij; Mark W Konijnenberg; J Frank W Nijsen
Journal:  Eur J Nucl Med Mol Imaging       Date:  2021-04-10       Impact factor: 9.236

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.