Literature DB >> 2227974

Evaluation of shoulder movement as a command control source.

M W Johnson1, P H Peckham.   

Abstract

The purpose of this study was to evaluate the use of scapular shoulder movement as a command control source. The focus of this study was on the evaluation of movement signals from quadriplegic subjects as well as on the processing of these signals for use as command inputs to a functional neuromuscular stimulation (FNS) hand-grasp system. The shoulder movement of three C5-level quadriplegic and nine normal subjects was studied using externally mounted two-degree-of-freedom transducers overlying the sternum and clavicles. The C5-level quadriplegic subjects tested had a considerably poorer range of motion than the normal subjects. The range of motion was greatest in elevation but was coupled with a significant component of retraction. The vertical command resolution of the quadriplegic subjects ranged from eight to 13 command levels, whereas the horizontal range contained four or fewer command levels. Normal subjects were able to produce 26 to 79 command levels along the vertical axis and 18 to 85 along the horizontal axis. Subjects were able to maintain a static command level to within several percent of their range in trials lasting from 10 to 30 s. The quadriplegic subjects performed poorly in tasks where they were required to move to a point along the horizontal or vertical central axis and then along the opposite axis. The normal subjects were readily able to perform these tasks. The interference with the command signal due to movement of the opposite extremity was significant, with a maximum error ranging between 25 and 86% along the vertical axis and between 38 and 105% along the horizontal axis. Rise time and normalized velocity (velocity divided by the size of the movement) were found to be suitable for distinguishing different types of shoulder movements independent of the size of the movement. Shoulder movement in quadriplegics is suitable as a command control source for a FNS hand-grasp system requiring one proportional command signal and at least one logical command signal with appropriate processing of the signals. The available transducers are cosmetically acceptable and are easy to don and doff. Use of shoulder movement as a command control source does not interfere with other activities of the user such as eating or talking. Shoulder movement also provides a command control source that is easy for the user to learn and provides some feedback to the user through shoulder proprioception.

Entities:  

Mesh:

Year:  1990        PMID: 2227974     DOI: 10.1109/10.58598

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  9 in total

1.  Control of a hand grasp neuroprosthesis using an electroencephalogram-triggered switch: demonstration of improvements in performance using wavepacket analysis.

Authors:  J M Heasman; T R D Scott; L Kirkup; R Y Flynn; V A Vare; C R Gschwind
Journal:  Med Biol Eng Comput       Date:  2002-09       Impact factor: 2.602

2.  A novel five degree of freedom user command controller in people with spinal cord injury and non-injured for full upper extremity neuroprostheses, wearable powered orthoses and prosthetics.

Authors:  Timothy R D Scott; Veronica A Vare
Journal:  Med Biol Eng Comput       Date:  2012-12-13       Impact factor: 2.602

3.  Grasp synthesis for upper-extremity FNS. Part 1. Automated method for synthesising the stimulus map.

Authors:  K L Kilgore; P H Peckham
Journal:  Med Biol Eng Comput       Date:  1993-11       Impact factor: 2.602

Review 4.  Brain-controlled muscle stimulation for the restoration of motor function.

Authors:  Christian Ethier; Lee E Miller
Journal:  Neurobiol Dis       Date:  2014-10-28       Impact factor: 5.996

5.  Continuous neuronal ensemble control of simulated arm reaching by a human with tetraplegia.

Authors:  E K Chadwick; D Blana; J D Simeral; J Lambrecht; S P Kim; A S Cornwell; D M Taylor; L R Hochberg; J P Donoghue; R F Kirsch
Journal:  J Neural Eng       Date:  2011-05-05       Impact factor: 5.379

6.  Command control for functional electrical stimulation hand grasp systems using miniature accelerometers and gyroscopes.

Authors:  K Y Tong; A F T Mak; W Y Ip
Journal:  Med Biol Eng Comput       Date:  2003-11       Impact factor: 2.602

7.  Implant provision of key, pinch and power grips in a C6 tetraplegic.

Authors:  T A Perkins; G S Brindley; N D Donaldson; C E Polkey; D N Rushton
Journal:  Med Biol Eng Comput       Date:  1994-07       Impact factor: 2.602

8.  Neuroprosthesis for individuals with spinal cord injury.

Authors:  Kevin L Kilgore; Kimberly D Anderson; P Hunter Peckham
Journal:  Neurol Res       Date:  2020-07-30       Impact factor: 2.529

9.  Myoelectric signal from below the level of spinal cord injury as a command source for an implanted upper extremity neuroprosthesis - a case report.

Authors:  Elizabeth Heald; Kevin Kilgore; Ronald Hart; Christa Moss; P Hunter Peckham
Journal:  J Neuroeng Rehabil       Date:  2019-08-02       Impact factor: 4.262

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.