This report describes the development of a compact ion attachment mass spectrometry system. A single turbomolecular pump was employed to fill the basic requirements for vacuum conditions simply and cost-effectively, without the need for a differential pumping stage. A Li(+) ion source was placed in the first of two vacuum chambers; a 0.4 mm aperture allowed the product ions to enter the second chamber for mass analysis. With the present system, any chemical species, including radical intermediates, can be detected at atmospheric pressure in real-time. The minimum detectable amount (at S/N = 3) of toluene was around 1.3 × 10(-12) g/s with a linearity greater than 10(4). For illustrative purposes, we tested the system on laboratory air and on aroma compounds in the headspace of the Yuzu plant, Citrus junos.

Entities:  

Year:  2012        PMID: 22278323     DOI: 10.1007/s13361-011-0302-x

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  7 in total

1.  Alkali-metal ion/molecule association reactions and their applications to mass spectrometry

Authors: 
Journal:  Mass Spectrom Rev       Date:  2000-05       Impact factor: 10.946

Review 2.  Mass spectrometry of free radicals.

Authors:  Michel Sablier; Toshihiro Fujii
Journal:  Chem Rev       Date:  2002-09       Impact factor: 60.622

3.  Temperature-resolved thermal analysis of cisplatin by means of Li+ ion attachment mass spectrometry.

Authors:  Seiji Takahashi; Yuki Kitahara; Megumi Nakamura; Yoshiro Shiokawa; Toshihiro Fujii
Journal:  Phys Chem Chem Phys       Date:  2010-02-24       Impact factor: 3.676

4.  Development of a tabletop time-of-flight mass spectrometer with an ion attachment ionization technique.

Authors:  Naoaki Saito; Jyun-ichi Nanjyo; Yasuyuki Taneda; Yoshiro Shiokawa; Mitsumori Tanimoto
Journal:  Rapid Commun Mass Spectrom       Date:  2007       Impact factor: 2.419

5.  Sodium ion attachment reactions in an ion trap mass spectrometer

Authors: 
Journal:  Rapid Commun Mass Spectrom       Date:  2000       Impact factor: 2.419

6.  Ion attachment mass spectrometry combined with infrared image furnace for thermal analysis: evolved gas analysis studies.

Authors:  Yuki Kitahara; Seiji Takahashi; Noriyuki Kuramoto; Martin Sala; Takahisa Tsugoshi; Michel Sablier; Toshihiro Fujii
Journal:  Anal Chem       Date:  2009-04-15       Impact factor: 6.986

7.  Identification and characterization of volatile components of the Japanese sour citrus fruit Citrus nagato-yuzukichi Tanaka.

Authors:  Yoshihiko Akakabe; Mei Sakamoto; Yukinori Ikeda; Mamoru Tanaka
Journal:  Biosci Biotechnol Biochem       Date:  2008-07-07       Impact factor: 2.043

  7 in total
  1 in total

1.  Gas-phase lithium cation basicity: revisiting the high basicity range by experiment and theory.

Authors:  Charly Mayeux; Peeter Burk; Jean-Francois Gal; Ivari Kaljurand; Ilmar Koppel; Ivo Leito; Lauri Sikk
Journal:  J Am Soc Mass Spectrom       Date:  2014-09-05       Impact factor: 3.109

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.