Literature DB >> 22277152

A continuous description of intervertebral motion by means of spline interpolation of kinematic data extracted by videofluoroscopy.

Paolo Bifulco1, Mario Cesarelli, Tommaso Cerciello, Maria Romano.   

Abstract

In vivo analysis of intervertebral kinematics provides useful information about spinal disorders and performance of disk prostheses. Diagnosis of intervertebral instability is based on measurement of abnormal range of segmental motion in sagittal plane through functional flexion-extension radiography; however, this concise measure does not take into account the progression of segmental motion in between flexion and extension extremes. Fluoroscopy can support analysis of intervertebral kinematics during patient's motion with an acceptable X-ray dose. A spline-based method designed for a continuous-time description of intervertebral motion extracted by videofluoroscopy is proposed. Fluoroscopic sagittal sequences of lumbar spine were processed by an automated method based on template matching to track vertebrae. A smoothing spline interpolation of the estimated intervertebral kinematic data was performed and a continuous-time description of segmental rotation and translation was obtained; the smoothing parameter was chosen both to preserve motion and to reduce noise. Concise measurements were extracted by the continuous-time kinematics and compared with standard clinical measurements of intervertebral sagittal rotation and translation. The trajectory of instantaneous center of rotation, never presented before for in vivo spinal segments, was provided and compared with standard measurements of the finite center of rotation. Results showed a good agreement with standard clinical measurements: on average, absolute differences resulted 0.74 degree for sagittal rotation, 0.59 mm for translation and 1.02 mm for the x- and y-position of center of rotation. The proposed method offers an effective technique for the continuous-time description of intervertebral motion, maintaining standard clinical measurements for diagnosis of lumbar instability.
Copyright © 2012 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22277152     DOI: 10.1016/j.jbiomech.2011.12.022

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  6 in total

1.  Advanced Multi-Axis Spine Testing: Clinical Relevance and Research Recommendations.

Authors:  Timothy P Holsgrove; Nikhil R Nayak; William C Welch; Beth A Winkelstein
Journal:  Int J Spine Surg       Date:  2015-07-17

2.  Hierarchical model-based tracking of cervical vertebrae from dynamic biplane radiographs.

Authors:  Md Abedul Haque; William Anderst; Scott Tashman; G Elisabeta Marai
Journal:  Med Eng Phys       Date:  2012-10-31       Impact factor: 2.242

3.  Sagittal plane rotation center of lower lumbar spine during a dynamic weight-lifting activity.

Authors:  Zhan Liu; Tsung-Yuan Tsai; Shaobai Wang; Minfei Wu; Weiye Zhong; Jing-Sheng Li; Thomas Cha; Kirk Wood; Guoan Li
Journal:  J Biomech       Date:  2015-12-29       Impact factor: 2.712

4.  Prospective surgical solutions in degenerative spine: spinal simulation for optimal choice of implant and targeted device development.

Authors:  Monique Salchow-Gille; Bernhard Rieger; Clemens Reinshagen; Marek Molcanyi; Joschka Lemke; Uta Brautferger; Kerim Hakan Sitoci-Ficici; Witold Polanski; Thomas Pinzer; Gabriele Schackert
Journal:  Innov Surg Sci       Date:  2021-04-07

5.  ICR in human cadaveric specimens: An essential parameter to consider in a new lumbar disc prosthesis design.

Authors:  Amparo Vanaclocha-Saiz; Carlos M Atienza; Vicente Vanaclocha; Vicente Belloch; Juan Manuel Santabarbara; Pablo Jordá-Gómez; Leyre Vanaclocha
Journal:  N Am Spine Soc J       Date:  2020-07-20

6.  Measurement of intervertebral cervical motion by means of dynamic x-ray image processing and data interpolation.

Authors:  Paolo Bifulco; Mario Cesarelli; Maria Romano; Antonio Fratini; Mario Sansone
Journal:  Int J Biomed Imaging       Date:  2013-10-31
  6 in total