Literature DB >> 22275660

Haptic recreation of elbow spasticity.

Hyung-Soon Park1, Jonghyun Kim, Diane L Damiano.   

Abstract

The aim of this paper is to develop a haptic device capable of presenting standardized recreation of elbow spasticity. Using the haptic device, clinicians will be able to repeatedly practice the assessment of spasticity without requiring patient involvement, and these practice opportunities will help improve accuracy and reliability of the assessment itself. Haptic elbow spasticity simulator (HESS) was designed and prototyped according to mechanical requirements to recreate the feel of elbow spasticity. Based on the data collected from subjects with elbow spasticity, a mathematical model representing elbow spasticity is proposed. As an attempt to differentiate the feel of each score in Modified Ashworth Scale (MAS), parameters of the model were obtained respectively for three different MAS scores 1, 1+, and 2. The implemented haptic recreation was evaluated by experienced clinicians who were asked to give MAS scores by manipulating the haptic device. The clinicians who participated in the study were blinded to each other's scores and to the given models. They distinguished the three models and the MAS scores given to the recreated models matched 100% with the original MAS scores from the patients.

Entities:  

Mesh:

Year:  2011        PMID: 22275660      PMCID: PMC3732826          DOI: 10.1109/ICORR.2011.5975462

Source DB:  PubMed          Journal:  IEEE Int Conf Rehabil Robot        ISSN: 1945-7898


  14 in total

1.  Time-varying stiffness of human elbow joint during cyclic voluntary movement.

Authors:  D J Bennett; J M Hollerbach; Y Xu; I W Hunter
Journal:  Exp Brain Res       Date:  1992       Impact factor: 1.972

2.  Reliability of the Tardieu Scale for assessing spasticity in children with cerebral palsy.

Authors:  Jean-Michel Gracies; Kim Burke; Nancy J Clegg; Richard Browne; Charter Rushing; Darcy Fehlings; Dennis Matthews; Ann Tilton; Mauricio R Delgado
Journal:  Arch Phys Med Rehabil       Date:  2010-03       Impact factor: 3.966

3.  What does the Ashworth scale really measure and are instrumented measures more valid and precise?

Authors:  Diane L Damiano; Jeffrey M Quinlivan; Bryan F Owen; Patricia Payne; Karen C Nelson; Mark F Abel
Journal:  Dev Med Child Neurol       Date:  2002-02       Impact factor: 5.449

4.  The pathophysiology of spasticity.

Authors:  G Sheean
Journal:  Eur J Neurol       Date:  2002-05       Impact factor: 6.089

5.  System identification of tendon reflex dynamics.

Authors:  L Q Zhang; H Huang; J A Sliwa; W Z Rymer
Journal:  IEEE Trans Rehabil Eng       Date:  1999-06

6.  A neuromusculoskeletal model to simulate the constant angular velocity elbow extension test of spasticity.

Authors:  Terry K K Koo; Arthur F T Mak
Journal:  Med Eng Phys       Date:  2006-01       Impact factor: 2.242

Review 7.  Clinical assessment of spasticity in children with cerebral palsy: a critical review of available instruments.

Authors:  Vanessa A B Scholtes; Jules G Becher; Anita Beelen; Gustaaf J Lankhorst
Journal:  Dev Med Child Neurol       Date:  2006-01       Impact factor: 5.449

8.  Linear spring-damper model of the hypertonic elbow: reliability and validity.

Authors:  Patrick H McCrea; Janice J Eng; Antony J Hodgson
Journal:  J Neurosci Methods       Date:  2003-09-30       Impact factor: 2.390

9.  Interrater reliability of a modified Ashworth scale of muscle spasticity.

Authors:  R W Bohannon; M B Smith
Journal:  Phys Ther       Date:  1987-02

10.  Neuromuscular modeling of spasticity in cerebral palsy.

Authors:  James W Fee; Richard A Foulds
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2004-03       Impact factor: 3.802

View more
  4 in total

1.  Haptic perception of multi-joint hypertonia during simulated patient-therapist physical tele-interaction.

Authors:  D Piovesan; A Melendez-Calderon; F A Mussa-Ivaldi
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2013

2.  Accuracy and reliability of haptic spasticity assessment using HESS (Haptic Elbow Spasticity Simulator).

Authors:  Jonghyun Kim; Hyung-Soon Park; Diane L Damiano
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2011

3.  Development of a Haptic Elbow Spasticity Simulator (HESS) for improving accuracy and reliability of clinical assessment of spasticity.

Authors:  Hyung-Soon Park; Jonghyun Kim; Diane L Damiano
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2012-05-02       Impact factor: 3.802

4.  Therapist recognition of impaired muscle groups in simulated multi-joint hypertonia.

Authors:  A Melendez-Calderon; D Piovesan; F A Mussa-Ivaldi
Journal:  IEEE Int Conf Rehabil Robot       Date:  2013-06
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.