Literature DB >> 22270453

An evaluation of contrast medium spread on caudal epidurography with the needle positioned toward the affected side in patients with unilateral lumbosacral radiculopathy.

Jae Hoon Lee1, Duck Mi Yoon, Tae Dong Kwon, Kyung Bong Yoon.   

Abstract

OBJECTIVE: We used caudal epidurography to compare the spread of contrast medium when the needle was inserted toward the affected side in patients with unilateral radiculopathy undergoing caudal steroid injection.
MATERIALS AND METHODS: We enrolled 24 patients with unilateral radiculopathy. A block needle was positioned toward the affected side in the sacral epidural space. After 5 mL of iodinated contrast medium was injected, a standardized anteroposterior view was imaged. Using Adobe Photoshop software, contrast medium spread was assessed by counting pixels within the areas spread on the affected side and on the opposite side, and the pixel counts of the two sides were compared. Spinal nerve root filling was also assessed.
RESULTS: The pixel count within the area of contrast medium spread on the side with the needle was significantly greater than that of the opposite side (mean [SD] 41,368.6 [13,143.1] vs 15,165.3 (10,698.1), P < 0.001]. However, 13.6% of the study patients had greater spread on the opposite side. The rates of L5 and S1 nerve root filling in the affected side were 18.2% and 36.4% respectively.
CONCLUSIONS: When a needle was intentionally inserted toward the side with radiculopathy, the spread of contrast medium and number of delineated roots tended to be greater on the side with the needle, compared with those on the opposite side. However, the pattern of contrast medium spread in the sacral epidural space varied and some patients even had greater spread on the opposite side.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22270453     DOI: 10.1007/s00256-011-1354-5

Source DB:  PubMed          Journal:  Skeletal Radiol        ISSN: 0364-2348            Impact factor:   2.199


  16 in total

1.  Lateral cervical epidural catheter placement for continuous unilateral upper extremity analgesia and sympathetic block.

Authors:  T Buchheit; J C Crews
Journal:  Reg Anesth Pain Med       Date:  2000 May-Jun       Impact factor: 6.288

2.  Lateral cervical epidural catheter placement using nerve stimulation for continuous unilateral upper extremity analgesia following a failed continuous peripheral nerve block.

Authors:  C Prusinkiewicz; S Lang; B C H Tsui
Journal:  Acta Anaesthesiol Scand       Date:  2005-04       Impact factor: 2.105

3.  Can epidurography help to predict the extent of epidural blockade?

Authors:  Emmanuel Marret; Stephanie Gibert; Francis Bonnet
Journal:  Anesthesiology       Date:  2005-02       Impact factor: 7.892

Review 4.  Epidural steroids in the management of chronic spinal pain: a systematic review.

Authors:  Salahadin Abdi; Sukdeb Datta; Andrea M Trescot; David M Schultz; Rajive Adlaka; Sairam L Atluri; Howard S Smith; Laxmaiah Manchikanti
Journal:  Pain Physician       Date:  2007-01       Impact factor: 4.965

5.  Intentional lateral epidural catheter placement for anterior cruciate ligament reconstruction.

Authors:  M Dauri; T Sidiropoulou; E Fabbi; P P Mariani; A F Sabato
Journal:  Acta Anaesthesiol Scand       Date:  2005-05       Impact factor: 2.105

6.  Evaluation of fluoroscopically guided caudal epidural injections.

Authors:  Laxmaiah Manchikanti; Kim A Cash; Vidyasagar Pampati; Carla D McManus; Kim S Damron
Journal:  Pain Physician       Date:  2004-01       Impact factor: 4.965

7.  Extradural analgesia revisited. A statistical study.

Authors:  E M Grundy; S Ramamurthy; K P Patel; M Mani; A P Winnie
Journal:  Br J Anaesth       Date:  1978-08       Impact factor: 9.166

8.  Influence of needle tip position on injectate spread in 406 interlaminar lumbar epidural steroid injections.

Authors:  Elizabeth L Whitlock; Keith H Bridwell; Louis A Gilula
Journal:  Radiology       Date:  2007-04-26       Impact factor: 11.105

9.  Correlation between the distribution of contrast medium and the extent of blockade during epidural anesthesia.

Authors:  Masataka Yokoyama; Motohiko Hanazaki; Hiromi Fujii; Satoshi Mizobuchi; Hideki Nakatsuka; Toru Takahashi; Masaki Matsumi; Mamoru Takeuchi; Kiyoshi Morita
Journal:  Anesthesiology       Date:  2004-06       Impact factor: 7.892

10.  Cephalic spreading levels after volumetric caudal epidural injections in chronic low back pain.

Authors:  K M Kim; H S Kim; K H Choi; W S Ahn
Journal:  J Korean Med Sci       Date:  2001-04       Impact factor: 2.153

View more
  4 in total

1.  Fluoroscopic evaluation of the influence of needle gauge on epidural spread in caudal block.

Authors:  Woo Seog Sim; Hue Jung Park; Ji Hye Kwon; Min Seok Oh; Hyun Joo Jung; Min Kyoung Cho; Jin Young Lee
Journal:  Medicine (Baltimore)       Date:  2019-05       Impact factor: 1.817

2.  Evaluation of Contrast Flow Patterns with Cervical Interlaminar Epidural Injection: Comparison of Midline and Paramedian Approaches.

Authors:  Byeongcheol Lee; Sang Eun Lee; Yong Han Kim; Jae Hong Park; Ki Hwa Lee; Eunsu Kang; Sehun Kim; Jaehwan Kim; Daeseok Oh
Journal:  Medicina (Kaunas)       Date:  2020-12-24       Impact factor: 2.430

3.  Needle Tip Position and Bevel Direction Have No Effect in the Fluoroscopic Epidural Spreading Pattern in Caudal Epidural Injections: A Randomized Trial.

Authors:  Won Kyoung Kwon; Ah Na Kim; Pil Moo Lee; Cheol Hwan Park; Jae Hun Kim
Journal:  Pain Res Manag       Date:  2016-04-24       Impact factor: 3.037

4.  Ultrasound-Guided Versus Fluoroscopy-Guided Caudal Epidural Steroid Injection for the Treatment of Unilateral Lower Lumbar Radicular Pain: Case-Controlled, Retrospective, Comparative Study.

Authors:  Ki Deok Park; Tai Kon Kim; Woo Yong Lee; JaeKi Ahn; Sung Hoon Koh; Yongbum Park
Journal:  Medicine (Baltimore)       Date:  2015-12       Impact factor: 1.817

  4 in total