Literature DB >> 22269770

Femoral cannulation with long arterial cannula in aortic dissection.

Nicola Luciani1, Amedeo Anselmi, Franco Glieca, Giuseppe Lauria, Raphael de Geest, Gianfederico Possati.   

Abstract

The optimal cannulation site in repair of DeBakey type I aortic dissection is controversial, and malperfusion during cardiopulmonary bypass is facilitated by retrograde flow. We propose the use of a long arterial cannula through the femoral artery to achieve a proximal antegrade perfusion. The tip of the cannula is placed in the true lumen of the distal aortic arch through the common femoral artery (Seldinger technique and transesophageal echography guidance). In 9 patients, there was one case of operative mortality (cardiac death), and no cases of perioperative stroke, bowel ischemia, severe renal failure, or local complications. Proximal perfusion can achieved rapidly and through an easily accessible site.
Copyright © 2012 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22269770     DOI: 10.1016/j.athoracsur.2011.10.018

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  1 in total

Review 1.  Cerebral malperfusion in acute aortic dissection.

Authors:  Kazumasa Orihashi
Journal:  Surg Today       Date:  2016-07-18       Impact factor: 2.549