Accuracy of office spirometry performed by trained primary-care physicians using the MIR Spirobank hand-held spirometer.

J Degryse1, J Buffels, Y Van Dijck, M Decramer, B Nemery.   

Abstract

BACKGROUND: With the availability of compact, portable, effective microspirometers, pulmonary function tests no longer need to be performed only in specialized laboratories. However, the perception persists that small flow-sensing devices are less accurate than volume-sensing spirometers.
OBJECTIVES: To study the accuracy of spirometry performed with the MIR Spirobank® and to investigate how accurately trained primary-care physicians can perform spirometry using a portable electronic spirometer.
METHODS: Patients with suspected occupational asthma were submitted to specific bronchial challenge tests in the pulmonary function laboratory according to published recommendations. Serial measurements were performed with the Jaeger MasterScope device (reference standard) or the Spirobank device. Data were generated from 908 parallel measurements on 34 patients. Furthermore, 16 patients with documented moderate to severe COPD were examined in a carousel set-up by four trained physicians who each used his/her own Spirobank device coupled to a laptop computer.
RESULTS: The Spirobank spirometer performed very well compared with the Jaeger MasterScope in a laboratory environment, displaying an underestimation of the forced expiratory volume in 1 s (FEV(1)) and FEV(1)/forced vital capacity (FVC) of 2-5%. High correlations were found for the pulmonary function parameters. The highest correlation was for FEV(1) (r(2) = 0.949) and the lowest for the maximum expiratory flow at 25% of FVC (MEF(25)) (r(2) = 0.864). Only 2% of the observed variation in the measurement results could be explained by the type of device.
CONCLUSIONS: The Spirobank device seems to be appropriate for research purposes if the standardized protocol is used correctly and the acceptability criteria are respected.
Copyright © 2012 S. Karger AG, Basel.

Entities:  

Mesh:

Year:  2012        PMID: 22269344     DOI: 10.1159/000334907

Source DB:  PubMed          Journal:  Respiration        ISSN: 0025-7931            Impact factor:   3.580


  15 in total

1.  Physiological effects of mixed-gas deep sea dives using a closed-circuit rebreather: a field pilot study.

Authors:  Emmanuel Dugrenot; Costantino Balestra; Emmanuel Gouin; Erwan L'Her; François Guerrero
Journal:  Eur J Appl Physiol       Date:  2021-08-25       Impact factor: 3.078

2.  Promoting risk reduction among young adults with asthma during wildfire smoke: A feasibility study.

Authors:  Julie Marie Postma; Tamara Odom-Maryon; Ana G Rappold; Hans Haverkamp; Solmaz Amiri; Ross Bindler; Justin Whicker; Von Walden
Journal:  Public Health Nurs       Date:  2021-10-11       Impact factor: 1.462

3.  A Review of Portable Electronic Spirometers: Implications for Asthma Self-Management.

Authors:  Delesha M Carpenter; Reina Jurdi; Courtney A Roberts; Michelle Hernandez; Robert Horne; Amy Chan
Journal:  Curr Allergy Asthma Rep       Date:  2018-08-25       Impact factor: 4.806

4.  Novel App-Based Portable Spirometer for the Early Detection of COPD.

Authors:  Ching-Hsiung Lin; Shih-Lung Cheng; Hao-Chien Wang; Wu-Huei Hsu; Kang-Yun Lee; Diahn-Warng Perng; Hen-I Lin; Ming-Shian Lin; Jong-Rung Tsai; Chin-Chou Wang; Sheng-Hao Lin; Cheng-Yi Wang; Chiung-Zuei Chen; Tsung-Ming Yang; Ching-Lung Liu; Tsai-Yu Wang; Meng-Chih Lin
Journal:  Diagnostics (Basel)       Date:  2021-04-27

5.  The RESPECT study: RESearch on the PrEvalence and the diagnosis of COPD and its Tobacco-related etiology: a study protocol.

Authors:  Elena Andreeva; Marina Pokhaznikova; Anatoly Lebedev; Irina Moiseeva; Anton Kozlov; Olga Kuznetsova; Jean-Marie Degryse
Journal:  BMC Public Health       Date:  2015-08-28       Impact factor: 3.295

6.  Predictors of poor-quality spirometry in two cohorts of older adults in Russia and Belgium: a cross-sectional study.

Authors:  Eralda Turkeshi; Dmitry Zelenukha; Bert Vaes; Elena Andreeva; Elena Frolova; Jean-Marie Degryse
Journal:  NPJ Prim Care Respir Med       Date:  2015-07-23       Impact factor: 2.871

7.  Short-term prognostic value of forced expiratory volume in 1 second divided by height cubed in a prospective cohort of people 80 years and older.

Authors:  Eralda Turkeshi; Bert Vaes; Elena Andreeva; Catharina Matheï; Wim Adriaensen; Gijs Van Pottelbergh; Jean-Marie Degryse
Journal:  BMC Geriatr       Date:  2015-02-25       Impact factor: 3.921

8.  Protocol of the Swiss Longitudinal Cohort Study (SWICOS) in rural Switzerland.

Authors:  Andreas W Schoenenberger; Franco Muggli; Gianfranco Parati; Augusto Gallino; Georg Ehret; Paolo M Suter; Renate Schoenenberger-Berzins; Therese J Resink; Paul Erne
Journal:  BMJ Open       Date:  2016-11-28       Impact factor: 2.692

9.  Spirometry is not enough to diagnose COPD in epidemiological studies: a follow-up study.

Authors:  Elena Andreeva; Marina Pokhaznikova; Anatoly Lebedev; Irina Moiseeva; Olga Kuznetsova; Jean-Marie Degryse
Journal:  NPJ Prim Care Respir Med       Date:  2017-11-14       Impact factor: 2.871

10.  Submarine rescue decompression procedure from hyperbaric exposures up to 6 bar of absolute pressure in man: effects on bubble formation and pulmonary function.

Authors:  Jean-Eric Blatteau; Julien Hugon; Olivier Castagna; Cédric Meckler; Nicolas Vallée; Yves Jammes; Michel Hugon; Jan Risberg; Christophe Pény
Journal:  PLoS One       Date:  2013-07-02       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.