Literature DB >> 22269272

A randomized clinical trial of biodegradable and titanium fixation systems in maxillofacial surgery.

G J Buijs1, N B van Bakelen, J Jansma, J G A M de Visscher, T J M Hoppenreijs, J E Bergsma, B Stegenga, R R M Bos.   

Abstract

Biodegradable fixation systems could reduce or delete the problems associated with metallic systems, since removal is not necessary. The aim of this study was to establish the effectiveness and safety of biodegradable plates and screws as potential alternatives to metallic ones. This multi-center randomized controlled trial was conducted from December 2006 to July 2009. Included were patients who underwent mandibular and/or Le Fort I osteotomies and those with fractures of the mandible, maxilla, and zygoma. The patients were assigned to a titanium control group (KLS Martin) or to a biodegradable test group (Inion CPS). The primary outcome measure was 'bone healing 8 weeks post-operatively'. The Intention-To-Treat (ITT) analysis of 113 patients in the titanium group and 117 patients in the biodegradable group yielded a significant difference (p < 0.001), primarily because in 25 patients (21%) who were randomized to the biodegradable group, the surgeon made the decision to switch to titanium intra-operatively. Despite this 'inferior' primary outcome result, biodegradable plates and screws could be safely used when it was possible to apply them. The benefits of using biodegradable systems (fewer plate removal operations) should be confirmed during a follow-up of minimally 5 years (Controlled-trials.com ISRCTN number 44212338).

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22269272     DOI: 10.1177/0022034511434353

Source DB:  PubMed          Journal:  J Dent Res        ISSN: 0022-0345            Impact factor:   6.116


  21 in total

Review 1.  Comparison between resorbable plates vs. titanium plates for treatment of zygomatic fractures: a systematic review with meta-analysis.

Authors:  Bianca Cristina Lopes da Silva; Debora Souto-Souza; Glaciele Maria de Souza; Rafael Alvim Magesty; Bruna de Cassia Ávila; Endi Lanza Galvão; Saulo Gabriel Moreira Falci
Journal:  Oral Maxillofac Surg       Date:  2021-01-04

2.  Evaluation of the rigidity of sagittal split ramus osteotomy fixation using four designs of biodegradable and titanium plates--a numerical study.

Authors:  Safieh Albougha; Mhd Hassan Albogha; Mhd Ayham Darwich; Khaldoun Darwich
Journal:  Oral Maxillofac Surg       Date:  2015-03-19

3.  Use of the bioactive resorbable plate system for zygoma and zygomatic arch replacement and fixation with modified Crockett's method for maxillectomy: A technical note.

Authors:  Shintaro Sukegawa; Takahiro Kanno; Akane Shibata; Kenichi Matsumoto; Yuka Sukegawa-Takahashi; Kyousuke Sakaida; Yoshihiko Furuki
Journal:  Mol Clin Oncol       Date:  2017-05-23

4.  Complications of a poly-L-lactic acid and polyglycolic acid osteosynthesis device for internal fixation in maxillofacial surgery.

Authors:  Shintaro Sukegawa; Takahiro Kanno; Kenichi Matsumoto; Yuka Sukegawa-Takahashi; Masanori Masui; Yoshihiko Furuki
Journal:  Odontology       Date:  2018-02-07       Impact factor: 2.634

5.  Clinical and radiographic evaluation of biodegradable bone plates in the treatment of mandibular body fractures.

Authors:  Sherin Kamal Elhalawany; Bassel Tarakji; Sn Azzeghaiby; Ibrahim Alzoghaibi; Kusai Baroudi; Mohammad Zakaria Nassani
Journal:  Niger Med J       Date:  2015 Jan-Feb

6.  Cost-Effectiveness of a Biodegradable Compared to a Titanium Fixation System in Maxillofacial Surgery: A Multicenter Randomized Controlled Trial.

Authors:  N B van Bakelen; K M Vermeulen; G J Buijs; J Jansma; J G A M de Visscher; Th J M Hoppenreijs; J E Bergsma; B Stegenga; R R M Bos
Journal:  PLoS One       Date:  2015-07-20       Impact factor: 3.240

7.  The Clinical Feasibility of Newly Developed Thin Flat-Type Bioresorbable Osteosynthesis Devices for the Internal Fixation of Zygomatic Fractures: Is There a Difference in Healing Between Bioresorbable Materials and Titanium Osteosynthesis?

Authors:  Shintaro Sukegawa; Takahiro Kanno; Daiki Nagano; Akane Shibata; Yuka Sukegawa-Takahashi; Yoshihiko Furuki
Journal:  J Craniofac Surg       Date:  2016-11       Impact factor: 1.046

8.  Absorbable implants versus metal implants for the treatment of ankle fractures: A meta-analysis.

Authors:  Zong-Huan Li; Ai-Xi Yu; Xiao-Peng Guo; Bai-Wen Qi; Min Zhou; Wei-Yang Wang
Journal:  Exp Ther Med       Date:  2013-03-19       Impact factor: 2.447

9.  Complications of absorbable fixation in maxillofacial surgery: a meta-analysis.

Authors:  Liya Yang; Meibang Xu; Xiaolei Jin; Jiajie Xu; Jianjian Lu; Chao Zhang; Tian Tian; Li Teng
Journal:  PLoS One       Date:  2013-06-28       Impact factor: 3.240

Review 10.  Resorbable versus titanium plates for orthognathic surgery.

Authors:  Anirudha Agnihotry; Zbys Fedorowicz; Mona Nasser; Karanjot S Gill
Journal:  Cochrane Database Syst Rev       Date:  2017-10-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.