OBJECTIVE: The purpose of this study is to determine whether complications associated with combining biopsy and percutaneous fiducial seed placement in the abdomen and pelvis exceeds that of either procedure alone or prohibits completion of the combined procedure.
MATERIALS AND METHODS: A retrospective review was performed of 188 consecutive patients who underwent CT- or ultrasound-guided placement of fiducial seeds in the abdomen or pelvis, either alone (group 1, n = 117) or with concomitant biopsy (group 2, n = 71), from October 2005 through April 2010. Complications classified according to the Society of Interventional Radiology guidelines were compared between both groups using the Z test for proportions, as were the number of seeds per patient and seed migration and technical success rates.
RESULTS: One hundred eighty-eight patients underwent percutaneous placement of 533 fiducial seeds in the abdomen and pelvis. Eight patients (4.3%) had complications. Five were minor (four small hematomas and one pneumothorax) and three were major (two cases of bleeding and one of sepsis). There was no significant difference between groups with respect to minor complication rates, number of seeds placed per patient (p = 0.85), or technical success (p = 0.33). Significantly more major complications (p = 0.04) occurred in group 2, but the rate was similar to that for percutaneous biopsy alone as reported in the literature. Group 2 also had more seed migration (p = 0.02).
CONCLUSION: Biopsy and fiducial seed placement in the abdomen and pelvis can be performed in the same session rather than separately, with a high rate of technical success and without an increased risk of complications when compared with either procedure alone.

Entities:  

Mesh:

Year:  2012        PMID: 22268195     DOI: 10.2214/AJR.11.6431

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  4 in total

Review 1.  Fiducial marker placement for stereotactic body radiation therapy via convex probe endobronchial ultrasound: a case series and review of literature.

Authors:  Benjamin J Seides; John P Egan; Kim D French; Kevin L Kovitz; Neeraj R Desai
Journal:  J Thorac Dis       Date:  2018-03       Impact factor: 2.895

2.  Therapeutic usability of two different fiducial gold markers for robotic stereotactic radiosurgery of liver malignancies: A pilot study.

Authors:  Maria Marsico; Tommaso Gabbani; Lorenzo Livi; Maria Rosa Biagini; Andrea Galli
Journal:  World J Hepatol       Date:  2016-06-18

3.  Respiratory-gated Proton Beam Therapy for Hepatocellular Carcinoma Adjacent to the Gastrointestinal Tract without Fiducial Markers.

Authors:  Miu Mizuhata; Shigeyuki Takamatsu; Satoshi Shibata; Sayuri Bou; Yoshitaka Sato; Mariko Kawamura; Satoko Asahi; Yuji Tameshige; Yoshikazu Maeda; Makoto Sasaki; Tomoyasu Kumano; Satoshi Kobayashi; Kazutaka Yamamoto; Hiroyasu Tamamura; Toshifumi Gabata
Journal:  Cancers (Basel)       Date:  2018-02-21       Impact factor: 6.639

4.  Percutaneous fiducial marker placement prior to stereotactic body radiotherapy for malignant liver tumors: an initial experience.

Authors:  Kengo Ohta; Masashi Shimohira; Taro Murai; Junichi Nishimura; Hiromitsu Iwata; Hiroyuki Ogino; Takuya Hashizume; Yuta Shibamoto
Journal:  J Radiat Res       Date:  2016-01-28       Impact factor: 2.724

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.