Literature DB >> 22266518

Comparative resilience of clinical perimetric tests to induced levels of intraocular straylight.

Justyna D Oleszczuk1, Ciara Bergin, Eamon Sharkawi.   

Abstract

PURPOSE: To investigate the effect of intraocular straylight (IOS) induced by white opacity filters (WOF) on threshold measurements for stimuli employed in three perimeters: standard automated perimetry (SAP), pulsar perimetry (PP) and the Moorfields motion displacement test (MDT).
METHODS: Four healthy young (24-28 years old) observers were tested six times with each perimeter, each time with one of five different WOFs and once without, inducing various levels of IOS (from 10% to 200%). An increase in IOS was measured with a straylight meter. The change in sensitivity from baseline was normalized, allowing comparison of standardized (z) scores (change divided by the SD of normative values) for each instrument.
RESULTS: SAP and PP thresholds were significantly affected (P < 0.001) by moderate to large increases in IOS (50%-200%). The drop in motion displacement (MD) from baseline with WOF 5, was approximately 5 dB, in both SAP and PP which represents a clinically significant loss; in contrast the change in MD with MDT was on average 1 minute of arc, which is not likely to indicate a clinically significant loss.
CONCLUSIONS: The Moorfields MDT is more robust to the effects of additional straylight in comparison with SAP or PP.

Entities:  

Mesh:

Year:  2012        PMID: 22266518     DOI: 10.1167/iovs.11-8659

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  5 in total

1.  Assessing spatial and temporal properties of perimetric stimuli for resistance to clinical variations in retinal illumination.

Authors:  William H Swanson; Mitchell W Dul; Douglas G Horner; Tiffany Liu; Irene Tran
Journal:  Invest Ophthalmol Vis Sci       Date:  2014-01-20       Impact factor: 4.799

Review 2.  [Pulsar perimetry. A review and new results].

Authors:  M Gonzalez de la Rosa; M Gonzalez-Hernandez
Journal:  Ophthalmologe       Date:  2013-02       Impact factor: 1.059

3.  [Influence of dry eye syndrome on glaucoma diagnostic procedures].

Authors:  F Rüfer; C Erb
Journal:  Ophthalmologe       Date:  2012-11       Impact factor: 1.059

4.  Effects of different levels of intraocular stray light on kinetic perimetry findings.

Authors:  Kazunori Hirasawa; Nobuyuki Shoji; Karen Isono; Manami Tsuchiya
Journal:  PLoS One       Date:  2015-05-12       Impact factor: 3.240

5.  Diagnostic capability of Pulsar perimetry in pre-perimetric and early glaucoma.

Authors:  Kazunori Hirasawa; Natsumi Takahashi; Kazuhiro Matsumura; Masayuki Kasahara; Nobuyuki Shoji
Journal:  Sci Rep       Date:  2017-06-12       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.