Literature DB >> 22266477

Preconcentration and detection of chlorinated organic compounds and benzene.

Stephen T Hobson1, Sabina Cemalovic, Sanjay V Patel.   

Abstract

Remote and automated detection of organic compounds in subsurface aquifers is crucial to superfund monitoring and environmental remediation. Current monitoring techniques use expensive laboratory instruments and trained personnel. The use of a filled tubular preconcentrator combined with a chemicapacitive detector array presents an attractive option for the unattended monitoring of these compounds. Five preconcentrator materials were exposed to common target compounds of subsurface remediation projects (1,1,2-trichloroethane, trichloroethylene, t-1,2-dichloroethylene, benzene, and perchloroethylene). Rapid heating of the tube caused the collected, concentrated effluent to pass over the surface of a chemicapacitive detector array coated with four different sorbent polymers. A system containing a porous ladder polymer and the sensor array was subsequently used to sample the analytes injected onto sand in a laboratory test, simulating a subsurface environment. With extended collection times, effective detection limits of 5 ± 3 ppbV for 1,1,2-trichloroethane and 145 ± 60 ppbV for benzene were achieved. Effects of the preconcentrator material structure, the collection time, and sensor material on the system performance were observed. The resultant system presents a solution for remote, periodic monitoring of chlorinated organic compounds and other volatile organic compounds in a soil matrix.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22266477     DOI: 10.1039/c2an16053f

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   5.227


  3 in total

1.  Implications of Thermal Annealing on the Benzene Vapor Sensing Behavior of PEVA-Graphene Nanocomposite Threads.

Authors:  Sanjay V Patel; Sabina Cemalovic; William K Tolley; Stephen T Hobson; Ryan Anderson; Bernd Fruhberger
Journal:  ACS Sens       Date:  2018-02-14       Impact factor: 7.711

2.  Developments toward a low-cost approach for long-term, unattended vapor intrusion monitoring.

Authors:  Sanjay V Patel; William K Tolley
Journal:  Analyst       Date:  2014-08-07       Impact factor: 4.616

3.  Integrated Gas Sensing System of SWCNT and Cellulose Polymer Concentrator for Benzene, Toluene, and Xylenes.

Authors:  Jisun Im; Elizabeth S Sterner; Timothy M Swager
Journal:  Sensors (Basel)       Date:  2016-02-02       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.