Véronique A Cornelissen1, Johan Vanhaecke, André E Aubert, Robert H Fagard. 1. Research Centre for Cardiovascular and Respiratory Rehabilitation, Department of Rehabilitation Sciences, University of Leuven, K.U. Leuven, Leuven, Belgium. Veronique.cornelissen@faber.kuleuven.be
Abstract
BACKGROUND: Cross-sectional studies suggest, by use of heart rate variability (HRV), that partial re-innervation of the sinus node may occur after heart transplantation (HTx). Our aim was to test this hypothesis by examining HRV in long-term longitudinal follow-up study of HTx recipients. METHODS AND RESULTS: 14 HTx recipients (11 men) were studied 1-48 (median 13) months (baseline) and 119-172 (median 141) months after HTx (follow-up). At baseline and follow-up, electrocardiographic RR interval was continuously recorded in the supine position for 20 min. The signals were analyzed in the time domain and in the frequency domain by means of power spectral analysis. RR-interval decreased significantly from baseline to follow-up (p<0.05). This was associated with an increase of total power (p<0.001), absolute low frequency (p<0.001), and high frequency power (p<0.001), but unchanged relative low frequency and high frequency power. CONCLUSIONS: The observed changes in HRV during long-term follow-up after HTx are compatible with partial re-innervation of the cardiac sinus node, as has been suggested by cross-sectional studies. Copyright Â
BACKGROUND: Cross-sectional studies suggest, by use of heart rate variability (HRV), that partial re-innervation of the sinus node may occur after heart transplantation (HTx). Our aim was to test this hypothesis by examining HRV in long-term longitudinal follow-up study of HTx recipients. METHODS AND RESULTS: 14 HTx recipients (11 men) were studied 1-48 (median 13) months (baseline) and 119-172 (median 141) months after HTx (follow-up). At baseline and follow-up, electrocardiographic RR interval was continuously recorded in the supine position for 20 min. The signals were analyzed in the time domain and in the frequency domain by means of power spectral analysis. RR-interval decreased significantly from baseline to follow-up (p<0.05). This was associated with an increase of total power (p<0.001), absolute low frequency (p<0.001), and high frequency power (p<0.001), but unchanged relative low frequency and high frequency power. CONCLUSIONS: The observed changes in HRV during long-term follow-up after HTx are compatible with partial re-innervation of the cardiac sinus node, as has been suggested by cross-sectional studies. Copyright Â
Authors: Ahmed I Mahmoud; Caitlin C O'Meara; Matthew Gemberling; Long Zhao; Donald M Bryant; Ruimao Zheng; Joseph B Gannon; Lei Cai; Wen-Yee Choi; Gregory F Egnaczyk; Caroline E Burns; C Geoffrey Burns; Calum A MacRae; Kenneth D Poss; Richard T Lee Journal: Dev Cell Date: 2015-08-06 Impact factor: 12.270
Authors: Morcos Awad; Lawrence S C Czer; Margaret Hou; Sarah S Golshani; Michael Goltche; Michele De Robertis; Michelle Kittleson; Jignesh Patel; Babak Azarbal; Evan Kransdorf; Fardad Esmailian; Alfredo Trento; Jon A Kobashigawa Journal: J Am Heart Assoc Date: 2016-11-01 Impact factor: 5.501
Authors: Joanna Wdowczyk; Danuta Makowiec; Marcin Gruchała; Dorota Wejer; Zbigniew R Struzik Journal: Front Physiol Date: 2018-04-09 Impact factor: 4.566