Literature DB >> 22266330

Factors affecting the endothelial retention of targeted microbubbles: influence of microbubble shell design and cell surface projection of the endothelial target molecule.

Elham Khanicheh1, Martina Mitterhuber, Katharina Kinslechner, Lifen Xu, Jonathan R Lindner, Beat A Kaufmann.   

Abstract

BACKGROUND: In biologic systems, the arrest of circulating cells is mediated by adhesion molecules projecting their active binding domain above the cell surface to enhance bond formation and tether strength. Similarly, molecular spacers are used for ligands on particle-based molecular imaging agents. The aim of this study was to evaluate the influence of tether length for targeting ligands on ultrasound molecular imaging agents.
METHODS: Microbubbles bearing biotin at the end of variable-length polyethylene glycol spacer arms (MB(2000) and MB(3400)) were prepared. To assess in vivo attachment efficiency to endothelial counterligands that vary in their distance from the endothelial cell surface, contrast-enhanced ultrasound (CEU) molecular imaging of tumor necrosis factor-α-induced P-selectin (long distance) or intercellular adhesion molecule-2 (short distance) was performed with each agent in murine hind limbs. To assess the influence of the glycocalyx on microbubble attachment, CEU molecular imaging of intercellular adhesion molecule-2 was performed after degradation of the glycocalyx.
RESULTS: CEU molecular imaging targeted to P-selectin showed signal enhancement above control agent for MB(2000) and MB(3400), the degree of which was significantly higher for MB(3400) compared with MB(2000). CEU molecular imaging targeted to intercellular adhesion molecule-2 showed low overall signal for all agents and signal enhancement above control for MB(3400) only. Glycocalyx degradation increased signal for MB(3400) and MB(2000).
CONCLUSIONS: Microbubble targeting to endothelial ligands is influenced by (1) the tether length of the ligand, (2) the degree to which the endothelial target is projected from the cell surface, and (3) the status of the glycocalyx. These considerations are important for designing targeted imaging probes and understanding potential obstacles to molecular imaging.
Copyright © 2012 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22266330      PMCID: PMC3941177          DOI: 10.1016/j.echo.2011.12.016

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  24 in total

1.  Modulating targeted adhesion of an ultrasound contrast agent to dysfunctional endothelium.

Authors:  Gregory E R Weller; Flordeliza S Villanueva; Alexander L Klibanov; William R Wagner
Journal:  Ann Biomed Eng       Date:  2002-09       Impact factor: 3.934

2.  Binding and detachment dynamics of microbubbles targeted to P-selectin under controlled shear flow.

Authors:  Amol M Takalkar; Alexander L Klibanov; Joshua J Rychak; Jonathan R Lindner; Klaus Ley
Journal:  J Control Release       Date:  2004-05-18       Impact factor: 9.776

Review 3.  Adhesion receptors of the immune system.

Authors:  T A Springer
Journal:  Nature       Date:  1990-08-02       Impact factor: 49.962

Review 4.  Leukocyte-endothelial adhesion molecules.

Authors:  T M Carlos; J M Harlan
Journal:  Blood       Date:  1994-10-01       Impact factor: 22.113

Review 5.  Selectins.

Authors:  M P Bevilacqua; R M Nelson
Journal:  J Clin Invest       Date:  1993-02       Impact factor: 14.808

6.  The expression of human intercellular adhesion molecule-2 is refractory to inflammatory cytokines.

Authors:  P Nortamo; R Li; R Renkonen; T Timonen; J Prieto; M Patarroyo; C G Gahmberg
Journal:  Eur J Immunol       Date:  1991-10       Impact factor: 5.532

7.  Ultrasound assessment of inflammation and renal tissue injury with microbubbles targeted to P-selectin.

Authors:  J R Lindner; J Song; J Christiansen; A L Klibanov; F Xu; K Ley
Journal:  Circulation       Date:  2001-10-23       Impact factor: 29.690

8.  Effect of acoustic power on in vivo molecular imaging with targeted microbubbles: implications for low-mechanical index real-time imaging.

Authors:  Beat A Kaufmann; Chad L Carr; Todd Belcik; Aris Xie; Benjamin Kron; Qi Yue; Jonathan R Lindner
Journal:  J Am Soc Echocardiogr       Date:  2009-11-11       Impact factor: 5.251

9.  P-selectin must extend a sufficient length from the plasma membrane to mediate rolling of neutrophils.

Authors:  K D Patel; M U Nollert; R P McEver
Journal:  J Cell Biol       Date:  1995-12       Impact factor: 10.539

10.  Distinct molecular and cellular contributions to stabilizing selectin-mediated rolling under flow.

Authors:  Tadayuki Yago; Anne Leppänen; Haiying Qiu; Warren D Marcus; Matthias U Nollert; Cheng Zhu; Richard D Cummings; Rodger P McEver
Journal:  J Cell Biol       Date:  2002-08-12       Impact factor: 10.539

View more
  2 in total

Review 1.  Ultrasound imaging for risk assessment in atherosclerosis.

Authors:  David C Steinl; Beat A Kaufmann
Journal:  Int J Mol Sci       Date:  2015-04-29       Impact factor: 5.923

2.  Noninvasive ultrasound molecular imaging of the effect of statins on endothelial inflammatory phenotype in early atherosclerosis.

Authors:  Elham Khanicheh; Martina Mitterhuber; Lifen Xu; Stéphanie P Haeuselmann; Gabriela M Kuster; Beat A Kaufmann
Journal:  PLoS One       Date:  2013-03-15       Impact factor: 3.240

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.