3-Dimensional elastic registration system of prostate biopsy location by real-time 3-dimensional transrectal ultrasound guidance with magnetic resonance/transrectal ultrasound image fusion.

Osamu Ukimura1, Mihir M Desai, Suzanne Palmer, Samuel Valencerina, Mitchell Gross, Andre L Abreu, Monish Aron, Inderbir S Gill.   

Abstract

PURPOSE: We determined the accuracy of the novel Urostation 3-dimensional transrectal ultrasound system (Koelis, La Tranche, France) for image based mapping biopsies in a prostate phantom. The system is capable of 1) registering the 3-dimensional location of each biopsy track in the 3-dimensional prostate volume data and 2) performing elastic image fusion of transrectal ultrasound with magnetic resonance imaging.
MATERIALS AND METHODS: We used 3 CIRS-053 prostate phantoms containing 3 hypoechoic lesions to perform ultrasound guided biopsy and 3 CIRS-066 phantoms (Computerized Imaging Reference Systems, Norfolk, Virginia) containing 3 isoechoic but magnetic resonance imaging visible lesions to perform magnetic resonance fusion guided biopsy. Three targeted biopsies were done per lesion. Each biopsy tract was injected with gadolinium based magnetic resonance contrast mixed with india ink. Phantoms were then subjected to 1 mm slice magnetic resonance imaging and serial step sectioning to assess the accuracy of targeted biopsy.
RESULTS: A total of 27 ultrasound guided biopsies were targeted into 9 hypoechoic lesions. All 27 biopsies (100%) successfully hit the target lesion. For hypoechoic lesions mean ± SD procedural targeting error was 1.52 ± 0.78 mm and system registration error was 0.83 mm, resulting in an overall error of 2.35 mm. Of the 27 magnetic resonance fusion biopsies 24 (84%) hit the lesion. For isoechoic lesions mean procedural targeting error was 2.09 ± 1.28 mm, resulting in an overall error of 2.92 mm.
CONCLUSIONS: The novel, computer assisted, 3-dimensional transrectal ultrasound biopsy localization system achieved encouraging accuracy with less than 3 mm error for targeting hypoechoic and isoechoic lesions. The ability to register actual biopsy trajectory and perform elastic magnetic resonance/ultrasound image fusion is a significant advantage for future focal therapy application.
Copyright © 2012. Published by Elsevier Inc.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22266005     DOI: 10.1016/j.juro.2011.10.124

Source DB:  PubMed          Journal:  J Urol        ISSN: 0022-5347            Impact factor:   7.450


  49 in total

1.  Evaluation of the ESUR PI-RADS scoring system for multiparametric MRI of the prostate with targeted MR/TRUS fusion-guided biopsy at 3.0 Tesla.

Authors:  M C Roethke; T H Kuru; S Schultze; D Tichy; A Kopp-Schneider; M Fenchel; H-P Schlemmer; B A Hadaschik
Journal:  Eur Radiol       Date:  2013-10-03       Impact factor: 5.315

2.  Robotic Transrectal Ultrasound Guided Prostate Biopsy.

Authors:  Sunghwan Lim; Changhan Jun; Doyoung Chang; Doru Petrisor; Misop Han; Dan Stoianovici
Journal:  IEEE Trans Biomed Eng       Date:  2019-01-07       Impact factor: 4.538

Review 3.  Magnetic Resonance Imaging-Ultrasound Fusion-Guided Prostate Biopsy: Review of Technology, Techniques, and Outcomes.

Authors:  Michael Kongnyuy; Arvin K George; Ardeshir R Rastinehad; Peter A Pinto
Journal:  Curr Urol Rep       Date:  2016-04       Impact factor: 3.092

4.  Safety and Feasibility of Direct Magnetic Resonance Imaging-guided Transperineal Prostate Biopsy Using a Novel Magnetic Resonance Imaging-safe Robotic Device.

Authors:  Mark W Ball; Ashley E Ross; Kamyar Ghabili; Chunwoo Kim; Changhan Jun; Doru Petrisor; Li Pan; Jonathan I Epstein; Katarzyna J Macura; Dan S Stoianovici; Mohamad E Allaf
Journal:  Urology       Date:  2017-07-19       Impact factor: 2.649

5.  Multimodal Imaging in Focal Therapy Planning and Assessment in Primary Prostate Cancer.

Authors:  Hossein Jadvar
Journal:  Clin Transl Imaging       Date:  2017-04-10

6.  [New puncture techniques in urology using 3D-assisted imaging].

Authors:  M Ritter; M-C Rassweiler; J J Rassweiler; M S Michel
Journal:  Urologe A       Date:  2012-12       Impact factor: 0.639

7.  MR Safe Robot, FDA Clearance, Safety and Feasibility Prostate Biopsy Clinical Trial.

Authors:  Dan Stoianovici; Chunwoo Kim; Doru Petrisor; Changhan Jun; Sunghwan Lim; Mark W Ball; Ashley Ross; Katarzyna J Macura; Mohamad Allaf
Journal:  IEEE ASME Trans Mechatron       Date:  2016-10-20       Impact factor: 5.303

8.  Value of targeted prostate biopsy using magnetic resonance-ultrasound fusion in men with prior negative biopsy and elevated prostate-specific antigen.

Authors:  Geoffrey A Sonn; Edward Chang; Shyam Natarajan; Daniel J Margolis; Malu Macairan; Patricia Lieu; Jiaoti Huang; Frederick J Dorey; Robert E Reiter; Leonard S Marks
Journal:  Eur Urol       Date:  2013-03-17       Impact factor: 20.096

Review 9.  Current status of magnetic resonance imaging (MRI) and ultrasonography fusion software platforms for guidance of prostate biopsies.

Authors:  Jennifer K Logan; Soroush Rais-Bahrami; Baris Turkbey; Andrew Gomella; Hayet Amalou; Peter L Choyke; Bradford J Wood; Peter A Pinto
Journal:  BJU Int       Date:  2014-05-22       Impact factor: 5.588

Review 10.  Considerations for patient selection for focal therapy.

Authors:  John F Ward; Louis L Pisters
Journal:  Ther Adv Urol       Date:  2013-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.