Literature DB >> 22265559

Comparison of three different sample preparation procedures for the determination of traffic-related elements in airborne particulate matter collected on glass fiber filters.

Ivan N B Castilho1, Bernhard Welz, Maria Goreti R Vale, Jailson B de Andrade, Patricia Smichowski, Abdallah A Shaltout, Lígia Colares, Eduardo Carasek.   

Abstract

Three different procedures for sample preparation have been compared for the determination of Cu, Mo and Sb in airborne particulate matter (APM) collected on glass fiber filters using high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GF AAS). Direct solid sample analysis of the ground filters was compared with microwave-assisted acid leaching with aqua regia and ultrasound-assisted extraction also using aqua regia. The main absorption line at 324.754 nm or the secondary line at 216.509 nm was used for the determination of Cu, depending on the analyte content in the samples. The primary absorption line at 313.259 nm was used for Mo and the secondary line at 212.739 nm for Sb determination. The limits of detection (LOD, 3σ) found for the direct solid sampling method, based on ten atomizations of an unused filter were 15 μg g(-1) for all three analytes, corresponding to 40 ng m(-3) for a typical air volume of 1,440 m(3) collected over a period of 24h. The LOD for the other two methods were less than a factor of two inferior, but the total time required for an analysis was significantly longer. The repeatability of the measurements was between 3 and 9% (n=5), and the results obtained with the three methods did not show any significant difference. The ratio between the three analytes on the filters from areas of intense traffic was found to be around Cu:Mo:Sb≈4:1:1.4, which suggests that the source of all three elements is brake linings, i.e., related to automobile traffic. When the ratio deviated significantly from the above values, the source of contamination was assumed to be of different origin.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22265559     DOI: 10.1016/j.talanta.2011.11.066

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  ICP-MS Determination of Antimicrobial Metals in Microcapsules.

Authors:  Iva Rezić; Maja Somogyi Škoc; Mislav Majdak; Slaven Jurić; Katarina Sopko Stracenski; Kristina Vlahoviček-Kahlina; Marko Vinceković
Journal:  Molecules       Date:  2022-05-18       Impact factor: 4.927

2.  Spectroscopic Assessment of Platinum Group Elements of PM10 Particles Sampled in Three Different Areas in Jeddah, Saudi Arabia.

Authors:  Mohammad W Kadi; Iqbal Ismail; Nadeem Ali; Abdallah A Shaltout
Journal:  Int J Environ Res Public Health       Date:  2020-05-11       Impact factor: 3.390

3.  Validation of an analytical method based on the high-resolution continuum source flame atomic absorption spectrometry for the fast-sequential determination of several hazardous/priority hazardous metals in soil.

Authors:  Tiberiu Frentiu; Michaela Ponta; Raluca Hategan
Journal:  Chem Cent J       Date:  2013-03-01       Impact factor: 4.215

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.