Literature DB >> 22265545

Spectrofluorometric determination and chemical speciation of trace concentrations of tungsten species in water using the ion pairing reagent procaine hydrochloride.

M S El-Shahawi1, L A Al Khateeb.   

Abstract

A highly selective and low cost extractive spectrofluorimetric method was developed for determination of trace concentrations of tungsten (VI) in water. The method was based upon solvent extraction of the developed ion associate [(PQH(+))(2)·WO(4)(2-)] of the fluorescent ion-pairing reagent [2-(diethylamino)ethyl 4 aminobenzoate] hydrochloride namely procaine hydrochloride, PQH(+)·Cl(-) and tungstate (WO(4)(2-)) in aqueous solution of pH 6-7 followed by measuring the resulting fluorescence enhancement in n-hexane at λ(ex/em)=270/320nm. The fluorescence intensity of PQH(+)·Cl(-) increased linearly on increasing tungstate concentration in the range 25-250μgL(-1). The limits of detection (LOD) and quantification (LOQ) of tungsten (VI) were found 7.51 and 24.75μgL(-1), respectively. Chemical composition of the developed ion associate and the molar absorptivity at 270nm were found to be [(PQH(+))(2)·WO(4)(2-)] and 2.7×10(4)Lmol(-1)cm(-1), respectively. Other oxidation states (III, IV, V) of tungsten species could also be determined after oxidation with H(2)O(2) in aqueous solution to tungsten (VI). The method was applied for analysis of tungsten in certified reference material (IAEA Soil-7) and wastewater samples. The results were compared successfully (>95%) with the data of inductively coupled plasma-mass spectrometry (ICP-MS).
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22265545     DOI: 10.1016/j.talanta.2011.11.039

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  2 in total

1.  An Ultrasensitive Detection Platform for Mercury Ions Speciation in Water Using Procaine Hydrochloride Ion Pair Coupled Extractive Spectrofluorimetry.

Authors:  Dyab A Al-Eryani; Waqas Ahmad; Gharam I Mohammad; Faten M Ali Zainy; Hassan Alwael; Saleh O Bahaffi; Mohammad S El-Shahawi
Journal:  J Fluoresc       Date:  2018-12-04       Impact factor: 2.217

2.  A chronoamperometric screen printed carbon biosensor based on alkaline phosphatase inhibition for W(IV) determination in water, using 2-phospho-L-ascorbic acid trisodium salt as a substrate.

Authors:  Ana Lorena Alvarado-Gámez; María Asunción Alonso-Lomillo; Olga Domínguez-Renedo; María Julia Arcos-Martínez
Journal:  Sensors (Basel)       Date:  2015-01-22       Impact factor: 3.576

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.