Literature DB >> 22265540

Determination of carbofuran in surface water and biological tissue by sol-gel immunoaffinity extraction and on-line preconcentration/HPLC/UV analysis.

Luz E Vera-Avila1, Bani P Márquez-Lira, Marcos Villanueva, Rosario Covarrubias, Gustavo Zelada, Valérie Thibert.   

Abstract

A selective and simple analytical method for the trace level determination of carbofuran in complex environmental and biological samples was developed based on immunoaffinity extraction (IAE) followed by on-line preconcentration and HPLC/UV analysis of the purified extract. The immunosorbent for IAE was prepared by sol-gel encapsulation of monoclonal anti-carbofuran antibodies, and was fully characterized for capacity, repeatability, binding strength, binding kinetics and cross-reactivity. Method performance was evaluated with two different types of difficult samples: dam water and methanolic extracts of epithelial cervical-uterine tissue. Linear behavior and quantitative recoveries were obtained from the analysis of samples spiked with carbofuran at 0.2-4 ng/mL (dam water, 50 mL samples) and 10-40 ng/mL (biological tissue extract, 2 mL samples). RSD (n=7) and detection limits were, respectively, 10.1% (spike 0.40 ng/mL) and 0.13 ng/mL for dam water; 8.5% (spike 20 ng/mL) and 5 ng/mL for the biological tissue extract. The excellent sample purification achieved with the IAE column allows precise and accurate determination of carbofuran in complex matrices, even when using non-selective UV detection in the chromatographic analysis.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22265540     DOI: 10.1016/j.talanta.2011.11.032

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  A microfluidic chip containing a molecularly imprinted polymer and a DNA aptamer for voltammetric determination of carbofuran.

Authors:  Shuhuai Li; Jianping Li; Jinhui Luo; Zhi Xu; Xionghui Ma
Journal:  Mikrochim Acta       Date:  2018-05-11       Impact factor: 5.833

Review 2.  Application of Graphene and its Derivatives in Detecting Hazardous Substances in Food: A Comprehensive Review.

Authors:  Jinjin Pei; Ting Ren; Yigang Huang; Rui Chen; Wengang Jin; Shufeng Shang; Jinze Wang; Zhe Liu; Yinku Liang; A M Abd El-Aty
Journal:  Front Chem       Date:  2022-07-01       Impact factor: 5.545

3.  Promising post-consumer PET-derived activated carbon electrode material for non-enzymatic electrochemical determination of carbofuran hydrolysate.

Authors:  Sureshkumar Ayyalusamy; Susmita Mishra; Vembu Suryanarayanan
Journal:  Sci Rep       Date:  2018-09-03       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.