Literature DB >> 22264447

Semi-automatic software increases CT measurement accuracy but not response classification of colorectal liver metastases after chemotherapy.

Charlotte S van Kessel1, Maarten S van Leeuwen, Petronella O Witteveen, Thomas C Kwee, Helena M Verkooijen, Richard van Hillegersberg.   

Abstract

OBJECTIVES: This study evaluates intra- and interobserver variability of automatic diameter and volume measurements of colorectal liver metastases (CRLM) before and after chemotherapy and its influence on response classification.
METHODS: Pre-and post-chemotherapy CT-scans of 33 patients with 138 CRLM were evaluated. Two observers measured all metastases three times on pre-and post-chemotherapy CT-scans, using three different techniques: manual diameter (MD), automatic diameter (AD) and automatic volume (AV). RECIST 1.0 criteria were used to define response classification. For each technique, we assessed intra- and interobserver reliability by determining the intraclass correlation coefficient (α-level 0.05). Intra-observer agreement was estimated by the variance coefficient (%). For inter-observer agreement the relative measurement error (%) was calculated using Bland-Altman analysis. In addition, we compared agreement in response classification by calculating kappa-scores (κ) and estimating proportions of discordance between methods (%).
RESULTS: Intra-observer variability was 6.05%, 4.28% and 12.72% for MD, AD and AV, respectively. Inter-observer variability was 4.23%, 2.02% and 14.86% for MD, AD and AV, respectively. Chemotherapy marginally affected these estimates. Agreement in response classification did not improve using AD or AV (MD κ=0.653, AD κ=0.548, AV κ=0.548) and substantial discordance between observers was observed with all three methods (MD 17.8%, AD 22.2%, AV 22.2%).
CONCLUSION: Semi-automatic software allows repeatable and reproducible measurement of both diameter and volume measurements of CRLM, but does not reduce variability in response classification.
Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22264447     DOI: 10.1016/j.ejrad.2011.12.026

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  3 in total

1.  Semi-automatic 3D-volumetry of liver metastases from neuroendocrine tumors to improve combination therapy with 177Lu-DOTATOC and 90Y-DOTATOC.

Authors:  Matthaeus Cieciera; Clemens Kratochwil; Jan Moltz; Hans Ulrich Kauczor; Tim Holland Letz; Peter Choyke; Walter Mier; Uwe Haberkorn; Frederik L Giesel
Journal:  Diagn Interv Radiol       Date:  2016 May-Jun       Impact factor: 2.630

2.  Comparison of response evaluation criteria in solid tumors with volumetric measurements for estimation of tumor burden in pancreatic adenocarcinoma and hepatocellular carcinoma.

Authors:  Jessemae L Welsh; Kellie Bodeker; Elizabeth Fallon; Sundershan K Bhatia; John M Buatti; Joseph J Cullen
Journal:  Am J Surg       Date:  2012-08-14       Impact factor: 2.565

3.  Precision of manual two-dimensional segmentations of lung and liver metastases and its impact on tumour response assessment using RECIST 1.1.

Authors:  F H Cornelis; M Martin; O Saut; X Buy; M Kind; J Palussiere; T Colin
Journal:  Eur Radiol Exp       Date:  2017-10-30
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.