Shall we report cardiomegaly at routine computed tomography of the chest?

Marc J Gollub1, Neety Panu, Holly Delaney, Michael Sohn, Junting Zheng, Chaya S Moskowitz, Jurgen Rademaker, Jennifer Liu.   

Abstract

PURPOSE: To examine the accuracy of the cardiothoracic ratio (CTR) at routine computed tomography (CT) of the chest to diagnose cardiomegaly by using echocardiography (ECHO) as a criterion standard, and secondarily, to search for CT cardiac measurements correlating with left ventricular hypertrophy (LVH) at ECHO.
MATERIALS AND METHODS: We searched 2 databases: cancer patients who had chest CT who also underwent routine ECHO by one experienced cardiologist, from January to March 2008. Consecutive patients were enrolled who had chest radiography (CXR) within 1 month and ECHO within 6 months of CT. Cardiothoracic ratio was defined as the transverse greatest cardiac diameter from outer to outer myocardium on axial images divided by the transverse greatest thoracic diameter from inner to inner chest wall on axial images, as measured by 2 board-certified radiologists. Left ventricular short diameter on CT was measured from inner to inner myocardium. Left ventricular hypertrophy at ECHO was defined using the standard American Society of Echocardiography criteria. Other data captured included cardiac and chemotherapy history, and secondary signs of heart failure. The Pearson correlation coefficient (r) and Wilcoxon rank sum tests and receiver operating characteristic (ROC) curves were used for statistical analysis.
RESULTS: 101 patients, 52 men and 49 women, with a mean age of 58 years met the entry criteria. Cardiothoracic ratio at CXR and CT were highly correlated (r = 0.802) (P < 0.001). There was moderate ability of CT CTR to identify LVH (area under the receiver operating characteristic curve AUC = 0.70; 95% CI, 0.51-0.90). The CT left ventricular short diameter showed moderate correlation with the ECHO left ventricular internal diameter (r = 0.49) and left ventricular mass (r = 0.37).
CONCLUSION: In patients with cancer undergoing routine ECHO, the cardiothoracic ratio at routine CT scans was highly correlated with that at CXR. Preliminary estimates in this small study indicate a low likelihood of LVH when the CTR is less than 0.49.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22261772     DOI: 10.1097/RCT.0b013e318241e585

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  9 in total

1.  Under-reporting of cardiovascular findings on chest CT.

Authors:  Nicola Sverzellati; Teresa Arcadi; Luca Salvolini; Roberto Dore; Maurizio Zompatori; Manuela Mereu; Giuseppe Battista; Ilenia Martella; Francesco Toni; Luciano Cardinale; Erica Maffei; Fabio Maggi; Filippo Cademartiri; Tommaso Pirronti
Journal:  Radiol Med       Date:  2015-10-30       Impact factor: 3.469

2.  Cardiothoracic ratio in postmortem computed tomography: reliability and threshold for the diagnosis of cardiomegaly.

Authors:  Sebastian Winklhofer; Nicole Berger; Thomas Ruder; Marina Elliott; Paul Stolzmann; Michael Thali; Hatem Alkadhi; Garyfalia Ampanozi
Journal:  Forensic Sci Med Pathol       Date:  2013-10-31       Impact factor: 2.007

3.  The role of angiography in the congruence of cardiovascular measurements between autopsy and postmortem imaging.

Authors:  Renaud Troxler; Costin Minoiu; Paul Vaucher; Katarzyna Michaud; Francesco Doenz; Kewin Ducrot; Silke Grabherr
Journal:  Int J Legal Med       Date:  2017-07-24       Impact factor: 2.686

4.  Post-mortem whole body computed tomography of opioid (heroin and methadone) fatalities: frequent findings and comparison to autopsy.

Authors:  Sebastian Winklhofer; Eddie Surer; Garyfalia Ampanozi; Thomas Ruder; Paul Stolzmann; Marina Elliott; Andrea Oestreich; Thomas Kraemer; Michael Thali; Hatem Alkadhi; Wolf Schweitzer
Journal:  Eur Radiol       Date:  2014-03-06       Impact factor: 5.315

5.  The cardiothoracic ratio on post-mortem computer tomography.

Authors:  M Jotterand; F Doenz; S Grabherr; M Faouzi; S Boone; P Mangin; K Michaud
Journal:  Int J Legal Med       Date:  2016-02-17       Impact factor: 2.686

6.  Changes in Cross-Sectional Area and Transverse Diameter of the Heart on Inspiratory and Expiratory Chest CT: Correlation with Changes in Lung Size and Influence on Cardiothoracic Ratio Measurement.

Authors:  Hayato Tomita; Tsuneo Yamashiro; Shin Matsuoka; Shoichiro Matsushita; Yasuyuki Kurihara; Yasuo Nakajima
Journal:  PLoS One       Date:  2015-07-07       Impact factor: 3.240

7.  Hyperinflated lungs compress the heart during expiration in COPD patients: a new finding on dynamic-ventilation computed tomography.

Authors:  Yanyan Xu; Tsuneo Yamashiro; Hiroshi Moriya; Maho Tsubakimoto; Nanae Tsuchiya; Yukihiro Nagatani; Shin Matsuoka; Sadayuki Murayama
Journal:  Int J Chron Obstruct Pulmon Dis       Date:  2017-10-26

8.  Mediastinal pulmonary artery is associated with greater artery diameter and lingular division volume.

Authors:  Hitoshi Dejima; Yusuke Takahashi; Tai Hato; Katsutoshi Seto; Tetsuya Mizuno; Hiroaki Kuroda; Noriaki Sakakura; Masafumi Kawamura; Yukinori Sakao
Journal:  Sci Rep       Date:  2017-04-28       Impact factor: 4.379

9.  The Association of CT-measured Cardiac Indices with Lung Involvement and Clinical Outcome in Patients with COVID-19.

Authors:  Vahid Eslami; Alireza Abrishami; Ehsan Zarei; Nastaran Khalili; Zahra Baharvand; Morteza Sanei-Taheri
Journal:  Acad Radiol       Date:  2020-10-01       Impact factor: 3.173

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.