Literature DB >> 22259001

External counterpulsation for acute ischaemic stroke.

Sen Lin1, Ming Liu, Bo Wu, Zilong Hao, Jie Yang, Wendan Tao.   

Abstract

BACKGROUND: External counterpulsation (ECP) may improve cerebral blood flow, and it has been proposed as a potential therapy for patients with ischaemic stroke.
OBJECTIVES: To assess the efficacy and safety of ECP for acute ischaemic stroke. SEARCH
METHODS: We searched the Cochrane Stroke Group Trials Register (June 2011), Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library, 2011 Issue 2), MEDLINE (1948 to June 2011), EMBASE (1980 to June 2011), CINAHL (1982 to June 2011), AMED (Allied and Complementary Medicine) (1985 to June 2011), China Biological Medicine Database (CBM) (1978 to June 2011), Chinese National Knowledge Infrastructure (CNKI) (1979 to June 2011), Chinese Science and Technique Journals Database (VIP) (1989 to June 2011) and Wanfang Data (1984 to June 2011). We also searched ongoing trials registers, reference lists and relevant conference proceedings and contacted authors and manufacturers of external counterpulsation devices. SELECTION CRITERIA: Randomised controlled trials (RCTs) in which ECP (started within seven days of stroke onset) was compared with sham treatment or no treatment, or ECP plus routine treatment was compared with routine treatment alone, in patients with acute ischaemic stroke. DATA COLLECTION AND ANALYSIS: Two review authors independently assessed trial quality and extracted data, checked for adverse events data and contacted trialists for missing information. MAIN
RESULTS: We included two trials involving 160 patients. Numbers of death or dependent patients at the end of at least three months follow-up were not reported in either of the included trials. The outcome measure used in the included trials was only the number of participants with improvement of neurological impairment after treatment according to the Modified Edinburgh-Scandinavian Stroke Scale (MESSS) or self-making criteria. ECP was associated with a significant increase in the number of participants whose neurological impairment improved (risk ratio (RR) 1.75, 95% confidence interval (CI) 1.37 to 2.23). Only one trial reported no adverse events. AUTHORS'
CONCLUSIONS: The methodological quality of the included studies was poor, and reliable conclusions could not be drawn from the present data. High-quality and large-scale RCTs are needed.

Entities:  

Mesh:

Year:  2012        PMID: 22259001     DOI: 10.1002/14651858.CD009264.pub2

Source DB:  PubMed          Journal:  Cochrane Database Syst Rev        ISSN: 1361-6137


  5 in total

Review 1.  Collaterals: Implications in cerebral ischemic diseases and therapeutic interventions.

Authors:  Yasuo Nishijima; Yosuke Akamatsu; Phillip R Weinstein; Jialing Liu
Journal:  Brain Res       Date:  2015-03-11       Impact factor: 3.252

2.  A retrospective pilot study of correlation of cerebral augmentation effects of external counterpulsation with functional outcome after acute ischaemic stroke.

Authors:  Li Xiong; Wenhua Lin; Jinghao Han; Xiangyan Chen; Thomas Wai Hong Leung; Yannie Oi Yan Soo; Lawrence Ka Sing Wong
Journal:  BMJ Open       Date:  2015-09-08       Impact factor: 2.692

3.  An assessment of randomized controlled trials (RCTs) for non-communicable diseases (NCDs): more and higher quality research is required in less developed countries.

Authors:  Hong Fan; Fujian Song
Journal:  Sci Rep       Date:  2015-08-14       Impact factor: 4.379

4.  Enhanced External Counterpulsation Efficacy on Exercise Endurance in COPD Patients and Healthy Subjects: A Pilot Randomized Clinical Trial.

Authors:  Mingming Zhao; Yanqun Huang; Lian Li; Ling Zhou; Zhixin Wu; Yujun Liu; Haozhe Zhang; Caiyou Hu
Journal:  Int J Chron Obstruct Pulmon Dis       Date:  2020-01-07

5.  The Role of Hypothermia in Large Hemispheric Infarction: A Systematic Review and Meta-Analysis.

Authors:  Jing Li; Yanghui Gu; Gang Li; Lixin Wang; Xiaobin Cheng; Min Wang; Min Zhao
Journal:  Front Neurol       Date:  2020-10-27       Impact factor: 4.003

  5 in total