Literature DB >> 22258972

Excimer laser refractive surgery versus phakic intraocular lenses for the correction of moderate to high myopia.

Allon Barsam1, Bruce D S Allan.   

Abstract

BACKGROUND: Myopia is a condition in which the focusing power (refraction) of the eye is greater than that required for clear distance vision. There are two main types of surgical correction for moderate to high myopia; excimer laser and phakic intraocular lenses (IOLs). Excimer laser refractive surgery for myopia works by removing corneal stroma to lessen the refractive power of the cornea and to bring the image of a viewed object into focus onto the retina rather than in front of it. Phakic IOLs for the treatment of myopia work by diverging light rays so that the image of a viewed object is brought into focus onto the retina rather than in front of the retina. They can be placed either in the anterior chamber of the eye in front of the iris or in the posterior chamber of the eye between the iris and the natural lens.
OBJECTIVES: The aim of this review is to compare the effect of excimer laser refractive surgery versus phakic IOLs for the correction of moderate to high myopia. SEARCH
METHODS: We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register) (The Cochrane Library 2011, Issue 11), MEDLINE (January 1950 to November 2011), EMBASE (January 1980 to November 2011), Latin American and Caribbean Literature on Health Sciences (LILACS) (January 1982 to November 2011), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com), ClinicalTrials.gov (www.clinicaltrials.gov) and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). There were no date or language restrictions in the electronic searches for trials. The electronic databases were last searched on 28 November 2011. SELECTION CRITERIA: We included randomised controlled trials (RCTs) comparing excimer laser refractive surgery and phakic IOLs for the correction of myopia greater than 6.0 diopters (D) spherical equivalent. DATA COLLECTION AND ANALYSIS: Two authors independently assessed trial quality and extracted data. We performed data analysis. We summarised data for outcomes using odds ratios. We used a fixed-effect model as only three trials were included in the review. MAIN
RESULTS: This review included three RCTs with a total of 228 eyes. The range of myopia of included patients was -6.0 D to -20.0 D of myopia with up to 4.0 D of myopic astigmatism. The percentage of eyes with uncorrected visual acuity (UCVA) of 20/20 or better at 12 months postoperative was not significantly different between the two groups. Phakic IOL surgery was safer than excimer laser surgical correction for moderate to high myopia as it results in significantly less loss of best spectacle corrected visual acuity (BSCVA) at 12 months postoperatively. However there is a low risk of developing early cataract with phakic IOLs. Phakic IOL surgery appears to result in better contrast sensitivity than excimer laser correction for moderate to high myopia. Phakic IOL surgery also scored more highly on patient satisfaction/preference questionnaires. AUTHORS'
CONCLUSIONS: The results of this review suggest that phakic IOLs are safer than excimer laser surgical correction for moderate to high myopia in the range of -6.0 to -20.0 D and phakic IOLs are preferred by patients. While phakic IOLs might be accepted clinical practice for higher levels of myopia (greater than or equal to 7.0 D of myopic spherical equivalent with or without astigmatism), it may be worth considering phakic IOL treatment over excimer laser correction for more moderate levels of myopia (less than or equal to 7.0 D of myopic spherical equivalent with or without astigmatism). Further RCTs adequately powered for subgroup analysis are necessary to further elucidate the ideal range of myopia for phakic IOLs.

Entities:  

Mesh:

Year:  2012        PMID: 22258972     DOI: 10.1002/14651858.CD007679.pub3

Source DB:  PubMed          Journal:  Cochrane Database Syst Rev        ISSN: 1361-6137


  9 in total

1.  Phakic intraocular lenses.

Authors:  Imtiaz A Chaudhry; M Alaa El Danasoury
Journal:  Saudi J Ophthalmol       Date:  2013-10

2.  SMILE for the Treatment of Residual Refractive Error After Cataract Surgery.

Authors:  Faruk Semiz; Anita Syla Lokaj; Njomza Hima Musa; Ceren Ece Semiz; Zekeriya Alp Demirsoy; Olcay Semiz
Journal:  Ophthalmol Ther       Date:  2022-05-28

3.  Visian implantable contact lens versus AcrySof Cachet phakic intraocular lenses: comparison of aberrmetric profiles.

Authors:  Mohamed Hm Hosny; Ahmad Mm Shalaby
Journal:  Clin Ophthalmol       Date:  2013-07-22

4.  Implantable collamer lens versus iris-fixed phakic intraocular lens implantation to correct myopia: a meta-analysis.

Authors:  Guan-Lu Liang; Jing Wu; Jun-Ting Shi; Jian Liu; Feng-Ying He; Wen Xu
Journal:  PLoS One       Date:  2014-08-12       Impact factor: 3.240

5.  Matched population comparison of visual outcomes and patient satisfaction between 3 modalities for the correction of low to moderate myopic astigmatism.

Authors:  Sri Ganesh; Sheetal Brar; Archana Pawar
Journal:  Clin Ophthalmol       Date:  2017-07-03

6.  Off-Label Use of Phakic Intraocular Lens with a "Piggyback" Technique.

Authors:  Tadgh Schempf; Hoon C Jung
Journal:  Case Rep Ophthalmol       Date:  2018-11-21

7.  Confounding sizing in posterior chamber phakic lens selection due to white-to-white measurement bias.

Authors:  JoaquIn Fernández; Manuel Rodríguez-Vallejo; Javier Martínez; Ana Tauste; Elisa Hueso; David P Piñero
Journal:  Indian J Ophthalmol       Date:  2019-03       Impact factor: 1.848

8.  Refractive, visual, and subjective quality of vision outcomes for very high myopia LASIK from - 10.00 to - 13.50 diopters.

Authors:  Avi Wallerstein; Joseph Wai Keung Kam; Mathieu Gauvin; Eser Adiguzel; Mounir Bashour; Ananda Kalevar; Mark Cohen
Journal:  BMC Ophthalmol       Date:  2020-06-17       Impact factor: 2.209

9.  Bilateral Toric Phakic Intraocular Lens Implantation for Correction of High Myopic Astigmatism in a Patient with Marfan Syndrome with Lens Coloboma: A Case Report.

Authors:  Bhupesh Singh; Sourabh Sharma; Suchit Dadia; Neha Bharti; Sudhank Bharti
Journal:  Case Rep Ophthalmol       Date:  2021-04-12
  9 in total