Literature DB >> 22258624

Results and relevance of molecular detection of pathogens by SeptiFast--a retrospective analysis in 75 critically ill children.

E Tschiedel1, J Steinmann, J Buer, J G Onnebrink, U Felderhoff-Müser, P-M Rath, C Dohna-Schwake.   

Abstract

BACKGROUND: Sepsis is a common cause of death in children. Early detection of bloodstream pathogens is crucial for the appropriate antibio­tic treatment. Blood cultures (BC) are the gold standard test used for detection. Recently, additional molecular detection methods of microbial DNA by multiplex PCR (SeptiFast, SF) have become available. AIM: Our retrospective study was aimed to compare results of BC to those of SF regarding results and therapeutic relevance.
METHOD: We identified a total of 110 SF samples in 75 patients with suspected systemic infection by retrospective chart review. Each patient underwent SF and BC testing simultaneously.
RESULTS: The initial analysis displayed no statistical significant difference in positive SF results compared to BC (p=0.19): in 26 of 110 samples (24%) microbial DNA was found. 19 BC (17%) showed microbial growth. 14 samples were positive in SF but negative in BC (13%). In patients who were pretreated with antibiotics (n=97) pathogens were identified in 24 samples by SF (25%) but only in 11 samples by BC (11%). Based on the clinical presentation and the spectrum of bacterial isolates 3 BC were considered contaminated. Considering this, SF yielded pathogens significantly more often than BC in the overall study population (p=0.04). SF results were available at least 31 h before BC results. Based on SF result antibiotic therapy was adjusted in 14 patients (13%).
CONCLUSION: Molecular detection of pathogens by SF was faster and more frequently positive than BC. We have therefore demonstrated that SF might be superior to BC in testing for bloodstream pathogens. Prospective multicentric studies are required to determine whether this hypothesis can be maintained. © Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22258624     DOI: 10.1055/s-0031-1285878

Source DB:  PubMed          Journal:  Klin Padiatr        ISSN: 0300-8630            Impact factor:   1.349


  13 in total

1.  Non-culture-based methods to diagnose bloodstream infection: Does it work?

Authors:  Miha Skvarc; David Stubljar; Petra Rogina; Achim J Kaasch
Journal:  Eur J Microbiol Immunol (Bp)       Date:  2013-06-05

Review 2.  Better tests, better care: improved diagnostics for infectious diseases.

Authors:  Angela M Caliendo; David N Gilbert; Christine C Ginocchio; Kimberly E Hanson; Larissa May; Thomas C Quinn; Fred C Tenover; David Alland; Anne J Blaschke; Robert A Bonomo; Karen C Carroll; Mary Jane Ferraro; Lisa R Hirschhorn; W Patrick Joseph; Tobi Karchmer; Ann T MacIntyre; L Barth Reller; Audrey F Jackson
Journal:  Clin Infect Dis       Date:  2013-12       Impact factor: 9.079

Review 3.  Accuracy of LightCycler(®) SeptiFast for the detection and identification of pathogens in the blood of patients with suspected sepsis: a systematic review and meta-analysis.

Authors:  Paul Dark; Bronagh Blackwood; Simon Gates; Danny McAuley; Gavin D Perkins; Ronan McMullan; Claire Wilson; Daniel Graham; Kate Timms; Geoffrey Warhurst
Journal:  Intensive Care Med       Date:  2014-11-22       Impact factor: 17.440

4.  Molecular diagnosis of sepsis: New aspects and recent developments.

Authors:  O Liesenfeld; L Lehman; K-P Hunfeld; G Kost
Journal:  Eur J Microbiol Immunol (Bp)       Date:  2014-03-14

Review 5.  Emerging Technologies for Molecular Diagnosis of Sepsis.

Authors:  Mridu Sinha; Julietta Jupe; Hannah Mack; Todd P Coleman; Shelley M Lawrence; Stephanie I Fraley
Journal:  Clin Microbiol Rev       Date:  2018-02-28       Impact factor: 26.132

Review 6.  Molecular assays for the diagnosis of sepsis in neonates.

Authors:  Mohan Pammi; Angela Flores; James Versalovic; Mariska Mg Leeflang
Journal:  Cochrane Database Syst Rev       Date:  2017-02-25

Review 7.  Commercial multiplex technologies for the microbiological diagnosis of sepsis.

Authors:  Evan E Lebovitz; Peter D Burbelo
Journal:  Mol Diagn Ther       Date:  2013-08       Impact factor: 4.074

8.  Clinical Relevance of Pathogens Detected by Multiplex PCR in Blood of Very-Low-Birth Weight Infants with Suspected Sepsis - Multicentre Study of the German Neonatal Network.

Authors:  Birte Tröger; Christoph Härtel; Jan Buer; Michael Dördelmann; Ursula Felderhoff-Müser; Thomas Höhn; Nico Hepping; Georg Hillebrand; Angela Kribs; Janina Marissen; Dirk Olbertz; Peter-Michael Rath; Susanne Schmidtke; Jens Siegel; Egbert Herting; Wolfgang Göpel; Joerg Steinmann; Anja Stein
Journal:  PLoS One       Date:  2016-07-29       Impact factor: 3.240

Review 9.  Multiplex PCR system for rapid detection of pathogens in patients with presumed sepsis - a systemic review and meta-analysis.

Authors:  Shy-Shin Chang; Wen-Han Hsieh; Ting-Shou Liu; Si-Huei Lee; Chih-Hung Wang; Hao-Chang Chou; Yee Hui Yeo; Ching-Ping Tseng; Chien-Chang Lee
Journal:  PLoS One       Date:  2013-05-29       Impact factor: 3.240

Review 10.  Bench-to-bedside review: Challenges of diagnosis, care and prevention of central catheter-related bloodstream infections in children.

Authors:  Susanne Janum; Walter Zingg; Volker Classen; Arash Afshari
Journal:  Crit Care       Date:  2013-08-28       Impact factor: 9.097

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.