Literature DB >> 22258019

Optic nerve sheath diameter used as ultrasonographic assessment of the incidence of raised intracranial pressure in preeclampsia: a pilot study.

Clément Dubost1, Agnès Le Gouez, Viridiana Jouffroy, Sandrine Roger-Christoph, Dan Benhamou, Frédéric J Mercier, Thomas Geeraerts.   

Abstract

BACKGROUND: In some cases of severe preeclampsia/eclampsia, brain imaging displays signs compatible with raised intracranial pressure. We aimed to estimate the incidence of raised intracranial pressure in preeclampsia using ocular ultrasonography.
METHODS: Optic nerve sheath diameter (ONSD) measurements were compared in 26 preeclamptic and 25 healthy pregnant women. For each optic nerve, two measurements were made (transverse plane and sagittal plane) using a 7.5 MHz ultrasound linear probe. Preeclamptic patients were followed-up until postpartum day 7.
RESULTS: Median ONSD values were significantly greater in preeclamptic patients compared with healthy pregnant women at delivery (5.4 mm (95% CI: 5.2, 5.7) vs. 4.5 mm (95% CI: 4.3, 4.8), P < 0.0001). At delivery, 5/26 (19%) of preeclamptic patients had ONSD values above 5.8 mm (value associated in the literature with 95% risk of raised intracranial pressure) whereas none of the healthy pregnant group had such high ONSD values. In the preeclamptic group, ONSD decreased after the third postpartum day. ONSD values at day 7 were not significantly different from those obtained in the normal pregnancy group (P = 0.10).
CONCLUSION: In about 20% of preeclamptic patients, ONSD reaches values compatible with intracranial pressure above 20 mmHg. Further work is needed to confirm this incidence and to better understand the diagnostic and therapeutic usefulness of this easy-to-do monitoring technique.

Entities:  

Mesh:

Year:  2012        PMID: 22258019     DOI: 10.1097/ALN.0b013e318246ea1a

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  22 in total

1.  Ultrasonographic optic nerve sheath diameter for predicting elevated intracranial pressure during laparoscopic surgery: a systematic review and meta-analysis.

Authors:  Eun Jung Kim; Bon-Nyeo Koo; Seung Ho Choi; Kyoungun Park; Min-Soo Kim
Journal:  Surg Endosc       Date:  2017-06-21       Impact factor: 4.584

Review 2.  Optic nerve sheath diameter: present and future perspectives for neurologists and critical care physicians.

Authors:  Piergiorgio Lochner; Marek Czosnyka; Andrea Naldi; Epameinondas Lyros; Paolo Pelosi; Shrey Mathur; Klaus Fassbender; Chiara Robba
Journal:  Neurol Sci       Date:  2019-07-31       Impact factor: 3.307

Review 3.  Echography in brain imaging in intensive care unit: State of the art.

Authors:  Anselmo Caricato; Sara Pitoni; Luca Montini; Maria Grazia Bocci; Pina Annetta; Massimo Antonelli
Journal:  World J Radiol       Date:  2014-09-28

4.  Effect of dexmedetomidine on intracranial pressure in patients undergoing gynecological laparoscopic surgery in Trendelenburg position through ultrasonographic measurement of optic nerve sheath diameter.

Authors:  Ting Zhu; Chen Yuan; Meijuan Qian; Lihong Zhao; Hui Li; Yang Xie
Journal:  Am J Transl Res       Date:  2022-09-15       Impact factor: 3.940

5.  Comparison of subfoveal choroidal thickness in healthy pregnancy and pre-eclampsia.

Authors:  J W Kim; M H Park; Y J Kim; Y T Kim
Journal:  Eye (Lond)       Date:  2015-11-06       Impact factor: 3.775

Review 6.  Ultrasound for the anesthesiologists: present and future.

Authors:  Abdullah S Terkawi; Dimitrios Karakitsos; Mahmoud Elbarbary; Michael Blaivas; Marcel E Durieux
Journal:  ScientificWorldJournal       Date:  2013-11-20

7.  Optic nerve sheath diameter as a marker for evaluation and prognostication of intracranial pressure in Indian patients: An observational study.

Authors:  Chetan G Shirodkar; S Manimala Rao; Dnyaneshwar P Mutkule; Yogesh R Harde; Pradeep M Venkategowda; M Uma Mahesh
Journal:  Indian J Crit Care Med       Date:  2014-11

8.  Accuracy of noninvasive intraocular pressure or optic nerve sheath diameter measurements for predicting elevated intracranial pressure in cryptococcal meningitis.

Authors:  Henry W Nabeta; Nathan C Bahr; Joshua Rhein; Nicholas Fossland; Agnes N Kiragga; David B Meya; Stephen J Dunlop; David R Boulware
Journal:  Open Forum Infect Dis       Date:  2014-10-11       Impact factor: 3.835

9.  Correlation of measurement of optic nerve sheath diameter using ultrasound with magnetic resonance imaging.

Authors:  Chetan G Shirodkar; Kartik Munta; S Manimala Rao; M Uma Mahesh
Journal:  Indian J Crit Care Med       Date:  2015-08

Review 10.  Near-infrared spectrometry in pregnancy: progress and perspectives, a review of literature.

Authors:  Anouar Jarraya; Smaoui Mohamed; Laabidi Sofiene; Kamel Kolsi
Journal:  Pan Afr Med J       Date:  2016-02-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.