Structural design of a newly developed pediatric circulatory assist device for Fontan circulation by using shape memory alloy fiber.

Y Shiraishi1, T K Sugai, A Tanaka, M Yoshizawa, T Yambe, A Yamada, M H Omran, T Shiga, T Kitano, K Kamiya, S Mochizuki, H Miura, D Homma, M Yamagishi.   

Abstract

Total cavopulmonary connection (TCPC) is commonly applied for the surgical treatment of congenital heart disease such as single ventricle in pediatric patients. Patients with no ventricle in pulmonary circulation are treated along with Fontan algorithm, in which the systemic venous return is diverted directly to the pulmonary artery without passing through subpulmonary ventricle. In order to promote the pulmonary circulation after Fontan procedure, we developed a newly designed pulmonary circulatory assist device by using shape memory alloy fibers. We developed a pulmonary circulatory assist device as a non-blood contacting mechanical support system in pediatric patients with TCPC. The device has been designed to be installed like a cuff around the ePTFE TCPC conduit, which can contract from outside. We employed a covalent type functional anisotropic shape memory alloy fiber (Biometal, Toki Corporation, Tokyo Japan) as a servo actuator of the pulmonary circulatory assist device. The diameter of this fiber was 100 microns, and its contractile frequency was 2-3 Hz. Heat generation with electric current contracts these fibers and the conduit. The maximum contraction ratio of this fiber is about 7% in length. In order to extend its contractile ratio, we fabricated and installed mechanical structural units to control the length of fibers. In this study, we examined basic contractile functions of the device in the mock system. As a result, the internal pressure of the conduit increased to 63 mmHg by the mechanical contraction under the condition of 400 msec-current supply in the mock examination with the overflow tank of 10 mmHg loading.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22256284     DOI: 10.1109/IEMBS.2011.6092060

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  2 in total

1.  Development of a thermodynamic control system for the Fontan circulation pulsation device using shape memory alloy fibers.

Authors:  Akihiro Yamada; Yasuyuki Shiraishi; Hidekazu Miura; Hashem Mohamed Omran Hashem; Yusuke Tsuboko; Masaaki Yamagishi; Tomoyuki Yambe
Journal:  J Artif Organs       Date:  2015-04-18       Impact factor: 1.731

2.  Etiological Peculiarities in Pediatric Heart Failure.

Authors:  Angela Butnariu; Gabriel Samasca
Journal:  Maedica (Bucur)       Date:  2015-09
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.