Literature DB >> 22256114

A high bandwidth fully implantable mouse telemetry system for chronic ECG measurement.

David M Russell1, Daniel McCormick, Andrew J Taberner, Simon C Malpas, David M Budgett.   

Abstract

We report on the development of a novel system that enables the wireless transmission of high-bandwidth physiological data from a freely moving mouse. The system employs inductive power transfer (IPT) to continuously power a battery-less transmitter using an array of overlapping planar coils placed under the animal. This arrangement provides a minimum of 20 mW at all locations and orientations across the mouse cage by selecting a coil which will sufficiently power the transmitter. Coil selection is performed by feedback control across the 2.4 GHz wireless link. A device was constructed utilizing this novel IPT system and was used to capture high-fidelity electrocardiogram (ECG) signal sampled at 2 kHz in mice. Various attributes of the ECG signal such as QT, QRS, and PR intervals could be obtained with a high degree of accuracy. This system potentially provides lifetime continuous high bandwidth measurement of physiological signals from a fully implanted telemeter in a freely moving mouse.

Entities:  

Mesh:

Year:  2011        PMID: 22256114     DOI: 10.1109/IEMBS.2011.6091889

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  4 in total

1.  Non-restraining EEG Radiotelemetry: Epidural and Deep Intracerebral Stereotaxic EEG Electrode Placement.

Authors:  Anna Papazoglou; Andreas Lundt; Carola Wormuth; Dan Ehninger; Christina Henseler; Julien Soós; Karl Broich; Marco Weiergräber
Journal:  J Vis Exp       Date:  2016-06-25       Impact factor: 1.355

2.  Wireless, battery-free subdermally implantable photometry systems for chronic recording of neural dynamics.

Authors:  Alex Burton; Sofian N Obaid; Abraham Vázquez-Guardado; Matthew B Schmit; Tucker Stuart; Le Cai; Zhiyuan Chen; Irawati Kandela; Chad R Haney; Emily A Waters; Haijiang Cai; John A Rogers; Luyao Lu; Philipp Gutruf
Journal:  Proc Natl Acad Sci U S A       Date:  2020-01-23       Impact factor: 11.205

3.  A Smart Wirelessly Powered Homecage for Long-Term High-Throughput Behavioral Experiments.

Authors:  Byunghun Lee; Mehdi Kiani; Maysam Ghovanloo
Journal:  IEEE Sens J       Date:  2015-09       Impact factor: 3.301

Review 4.  EEG Radiotelemetry in Small Laboratory Rodents: A Powerful State-of-the Art Approach in Neuropsychiatric, Neurodegenerative, and Epilepsy Research.

Authors:  Andreas Lundt; Carola Wormuth; Magdalena Elisabeth Siwek; Ralf Müller; Dan Ehninger; Christina Henseler; Karl Broich; Anna Papazoglou; Marco Weiergräber
Journal:  Neural Plast       Date:  2015-12-24       Impact factor: 3.599

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.