Literature DB >> 22254882

Image geometric corrections for a new EMCCD-based dual modular x-ray imager.

Bin Qu1, Ying Huang, Weiyuan Wang, Alexander N Cartwright, Albert H Titus, Daniel R Bednarek, Stephen Rudin.   

Abstract

An EMCCD-based dual modular x-ray imager was recently designed and developed from the component level, providing a high dynamic range of 53 dB and an effective pixel size of 26 μm for angiography and fluoroscopy. The unique 2 × 1 array design efficiently increased the clinical field of view, and also can be readily expanded to an MxN array implementation. Due to the alignment mismatches between the EMCCD sensors and the fiber optic tapers in each module, the output images or video sequences result in a misaligned 2048 × 1024 digital display if uncorrected. In this paper, we present a method for correcting display registration using a custom-designed two layer printed circuit board. This board was designed with grid lines to serve as the calibration pattern, and provides an accurate reference and sufficient contrast to enable proper display registration. Results show an accurate and fine stitching of the two outputs from the two modules.

Entities:  

Mesh:

Year:  2011        PMID: 22254882      PMCID: PMC3411313          DOI: 10.1109/IEMBS.2011.6090726

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  3 in total

1.  Image stitching using structure deformation.

Authors:  Jiaya Jia; Chi-Keung Tang
Journal:  IEEE Trans Pattern Anal Mach Intell       Date:  2008-04       Impact factor: 6.226

2.  Quantum Performance Analysis of an EMCCD-based X-ray Detector Using Photon Transfer Technique.

Authors:  Bin Qu; Andrew T Kuhls-Gilcrist; Ying Huang; Weiyuan Wang; Alexander N Cartwright; Albert H Titus; Daniel R Bednarek; Stephen Rudin
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2010-10-30

3.  Component Level Modular Design of a Solid State X-ray Image Intensifier for an M×N Array.

Authors:  Ying Huang; Bin Qu; Prateek Sharma; Andrew Kuhls-Gilcrist; Weiyuan Wang; Albert H Titus; Alexander N Cartwright; Daniel R Bednarek; Stephen Rudin
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2010-10-30
  3 in total
  1 in total

1.  Image acquisition, geometric correction and display of images from a 2×2 x-ray detector array based on Electron Multiplying Charge Coupled Device (EMCCD) technology.

Authors:  S N Swetadri Vasan; P Sharma; Ciprian N Ionita; A H Titus; A N Cartwright; D R Bednarek; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2013-03-06
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.