Frank-starling control of a left ventricular assist device.

Michael Charles Stevens1, Nicholas Richard Gaddum, Mark Pearcy, Robert F Salamonsen, Daniel Lee Timms, David Glen Mason, John F Fraser.   

Abstract

A physiological control system was developed for a rotary left ventricular assist device (LVAD) in which the target pump flow rate (LVADQ) was set as a function of left atrial pressure (LAP), mimicking the Frank-Starling mechanism. The control strategy was implemented using linear PID control and was evaluated in a pulsatile mock circulation loop using a prototyped centrifugal pump by varying pulmonary vascular resistance to alter venous return. The control strategy automatically varied pump speed (2460 to 1740 to 2700 RPM) in response to a decrease and subsequent increase in venous return. In contrast, a fixed-speed pump caused a simulated ventricular suction event during low venous return and higher ventricular volumes during high venous return. The preload sensitivity was increased from 0.011 L/min/mmHg in fixed speed mode to 0.47L/min/mmHg, a value similar to that of the native healthy heart. The sensitivity varied automatically to maintain the LAP and LVADQ within a predefined zone. This control strategy requires the implantation of a pressure sensor in the left atrium and a flow sensor around the outflow cannula of the LVAD. However, appropriate pressure sensor technology is not yet commercially available and so an alternative measure of preload such as pulsatility of pump signals should be investigated.

Entities:  

Mesh:

Year:  2011        PMID: 22254563     DOI: 10.1109/IEMBS.2011.6090314

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  4 in total

1.  Preload Sensitivity with TORVAD Counterpulse Support Prevents Suction and Overpumping.

Authors:  Jeffrey R Gohean; Erik R Larson; Raul G Longoria; Mark Kurusz; Richard W Smalling
Journal:  Cardiovasc Eng Technol       Date:  2019-06-11       Impact factor: 2.495

2.  Cannula Tip With Integrated Volume Sensor for Rotary Blood Pump Control: Early-Stage Development.

Authors:  Joshua Cysyk; Ray Newswanger; Eric Popjes; Walter Pae; Choon-Sik Jhun; Jenelle Izer; William Weiss; Gerson Rosenberg
Journal:  ASAIO J       Date:  2019 May/Jun       Impact factor: 2.872

3.  Preload-based Starling-like control of rotary blood pumps: An in-vitro evaluation.

Authors:  Mahdi Mansouri; Shaun D Gregory; Robert F Salamonsen; Nigel H Lovell; Michael C Stevens; Jo P Pauls; Rini Akmeliawati; Einly Lim
Journal:  PLoS One       Date:  2017-02-17       Impact factor: 3.240

4.  Control Strategy Design of a Microblood Pump Based on Heart-Rate Feedback.

Authors:  Teng Jing; Tianye Xin; Fangqun Wang; Zhihao Zhang; Ling Zhou
Journal:  Micromachines (Basel)       Date:  2022-02-24       Impact factor: 2.891

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.