Literature DB >> 22254505

Eye-surface conformable telemetric structure for polymer-based retinal prosthesis.

Joonsoo Jeong1, Seung Woo Lee, Kyousik Min, Kyungsik Eom, So Hyun Bae, Sung June Kim.   

Abstract

In this research, inductive telemetric structure for retinal prosthesis was developed based on Liquid Crystal Polymers. For power and data transmission into the polymer-based retinal implant which is conformable to eye surface, the designed coil was thermo-formed into convex shape. The geometric parameters of the coil were optimized using finite element method (FEM) simulations for maximizing coupling coefficient and quality factor. The electrical properties of fabricated coils were characterized and their power and data transmission performance was tested. The properties of deformed structure were compared to those of the planar structure. In vivo experiment were also conducted to confirm the functionality of telemetry system in implanted conditions as well as to estimate the influence of biological media upon link properties.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22254505     DOI: 10.1109/IEMBS.2011.6090256

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  4 in total

1.  Implantable electrical stimulation bioreactor with liquid crystal polymer-based electrodes for enhanced bone regeneration at mandibular large defects in rabbit.

Authors:  Chaebin Kim; Hoon Joo Yang; Tae Hyung Cho; Beom Seok Lee; Tae Mok Gwon; Soowon Shin; In Sook Kim; Sung June Kim; Soon Jung Hwang
Journal:  Med Biol Eng Comput       Date:  2019-12-18       Impact factor: 2.602

Review 2.  Conducting Polymers for Neural Prosthetic and Neural Interface Applications.

Authors:  Rylie Green; Mohammad Reza Abidian
Journal:  Adv Mater       Date:  2015-09-28       Impact factor: 30.849

3.  Magnetic Resonance Imaging Compatibility of the Polymer-based Cochlear Implant.

Authors:  Jin Ho Kim; Kyou Sik Min; Soon Kwan An; Joon Soo Jeong; Sang Beom Jun; Min Hyoung Cho; Young-Don Son; Zang-Hee Cho; Sung June Kim
Journal:  Clin Exp Otorhinolaryngol       Date:  2012-04-30       Impact factor: 3.372

4.  Investigation of Surgical Techniques for Optimization of Long-Term Outcomes of LCP-Based Retinal Prosthesis Implantation.

Authors:  So Hyun Bae; Joonsoo Jeong; Sung June Kim; Hum Chung; Jong-Mo Seo
Journal:  Transl Vis Sci Technol       Date:  2018-08-24       Impact factor: 3.283

  4 in total