Literature DB >> 22253065

Cell analysis in cerebrospinal fluid (CSF) using Sysmex® hematology analyzers XT-4000i and XE-5000: evaluation with CSF controls of the Joint German Society for Clinical Chemistry and Laboratory Medicine (DGKL).

Tilmann O Kleine1, Carl Thomas Nebe, Christa Löwer, Wolf-Jochen Geilenkeuser, Alexandra Dorn-Beineke.   

Abstract

In cerebrospinal fluid (CSF) analysis, hematology analyzers (HAs) Sysmex® XT-4000i and XE-5000, equipped with flow cytometry (FCM), were used to count cells and differentiate leukocytes into mononuclear and polymorphonuclear cells (MNCs, PMCs) applying body fluid mode. FCM was evaluated with 20 DGKL CSF controls containing viable human leukocytes and erythrocytes. HA values were compared with reference values by Passing/Bablok regression analysis to reveal conformity. Conformity of white blood cells (WBCs) was obtained with native leukocytes, counted in calibrated Fuchs-Rosenthal chamber as reference; red blood cell counts proved inaccurate. CV <40% with WBC counts <20 per μL impairs accuracy. Reference WBC differentiation was assayed using FACS Canto II™ and FC-500 SN with anti-CD45, anti-CD14, anti-CD16, anti-CD16/56 [Becton Dickinson (BD); Beckman Coulter (BC)]. BD FACS lysing solution®-no-wash-procedure was applied. BC pretreatment with Versalyse lysing solution was not recommended. MNCs (lymphocytes + monocytes) were significantly lower (∼14%) on both HAs; PMCs (granulocytes or sum of neutrophils + eosinophils + basophils: range 1-86 M/L) were significantly higher (∼2.2-fold). WBC HA differentiation is not reliable because MNC/PMC differentiation yielded lower and higher values than FACS-FCM references, respectively. This is attributed to incorrect discrimination of leukocytes with rounded/nonrounded nuclei; adding leukocytes with nonrounded nuclei to too low HA MNCs (about 40% not-activated) yielded P/B conformity; subtraction of leukocytes with nonrounded nuclei from elevated HA PMCs showed conformity (about 85% activated). Nucleus/activation state of leukocytes was assessed using microhistology. Sysmex XT-4000i and XE-5000 HAs systems are inappropriate for complete CSF cell analysis.
Copyright © 2012 International Society for Advancement of Cytometry.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22253065     DOI: 10.1002/cyto.a.22014

Source DB:  PubMed          Journal:  Cytometry A        ISSN: 1552-4922            Impact factor:   4.355


  5 in total

1.  Use of the Sysmex XT-4000i hematology analyzer in the differentiation of cerebrospinal fluid cells in children.

Authors:  Beata Zelazowska-Rutkowska; Janusz Zak; Malgorzata Wojtkowska; Justyna Zaworonek; Bogdan Cylwik
Journal:  J Clin Lab Anal       Date:  2018-11-28       Impact factor: 2.352

2.  Experience with CellaVision DM96 for peripheral blood differentials in a large multi-center academic hospital system.

Authors:  Marian A Rollins-Raval; Jay S Raval; Lydia Contis
Journal:  J Pathol Inform       Date:  2012-08-25

Review 3.  A narrative review of central nervous system involvement in acute leukemias.

Authors:  Dalma Deak; Nicolae Gorcea-Andronic; Valentina Sas; Patric Teodorescu; Catalin Constantinescu; Sabina Iluta; Sergiu Pasca; Ionut Hotea; Cristina Turcas; Vlad Moisoiu; Alina-Andreea Zimta; Simona Galdean; Jakob Steinheber; Ioana Rus; Sebastian Rauch; Cedric Richlitzki; Raluca Munteanu; Ancuta Jurj; Bobe Petrushev; Cristina Selicean; Mirela Marian; Olga Soritau; Alexandra Andries; Andrei Roman; Delia Dima; Alina Tanase; Olafur Sigurjonsson; Ciprian Tomuleasa
Journal:  Ann Transl Med       Date:  2021-01

4.  Automated Analysis of Cerebrospinal Fluid Cells Using Commercially Available Blood Cell Analysis Devices-A Critical Appraisal.

Authors:  Manfred Wick; Catharina C Gross; Hayrettin Tumani; Brigitte Wildemann; Martin Stangel
Journal:  Cells       Date:  2021-05-18       Impact factor: 6.600

5.  On-Chip Cell Staining and Counting Platform for the Rapid Detection of Blood Cells in Cerebrospinal Fluid.

Authors:  Yujin Lee; Byeongyeon Kim; Sungyoung Choi
Journal:  Sensors (Basel)       Date:  2018-04-07       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.