| Literature DB >> 22247646 |
Masayuki Kanematsu1, Hiroshi Kondo, Satoshi Goshima, Yusuke Tsuge, Haruo Watanabe, Noriyuki Moriyama.
Abstract
Pulmonary arteriovenous malformations (PAVMs) are often treated by pushable fibered or non-fibered microcoils, using an anchor or scaffold technique or with an Amplatzer plug through a guiding sheath. When performing percutaneous transcatheter microcoil embolization, there is a risk of coil migration, particularly with high-flow type PAVMs. The authors report on a unique treatment in a patient with a giant high-flow PAVM whose nidus had a maximum diameter of 6 cm. A detachable coil, not detached from a delivery wire (an anchored detachable coil), was first placed in the feeding artery under flow control by balloon occlusion, and then multiple microcoils were packed proximally to the anchored detachable coil. After confirming the stability of the microcoils during a gradual deflation of the balloon, we finally released the first detachable coil. The nidus was reduced in size to 15 mm at one year postoperatively.Entities:
Keywords: Balloon occlusion; Detachable coil; Embolization; High-flow type; Pulmonary arteriovenous malformation
Mesh:
Substances:
Year: 2011 PMID: 22247646 PMCID: PMC3253396 DOI: 10.3348/kjr.2012.13.1.111
Source DB: PubMed Journal: Korean J Radiol ISSN: 1229-6929 Impact factor: 3.500
Fig. 150-year-old man with giant, complex-type pulmonary arteriovenous malformation in right thorax.
A. Multiplanar reformatted coronal CT image showing high-flow type giant pulmonary arteriovenous malformation with two feeding arteries. One measured 10.5 mm in maximum diameter (arrow) and originated from lateral basal segment branch of right pulmonary artery (A9), while other measured 9.5 mm and originated from posterior basal segment branch (A10). Note giant nidus (asterisk), which measured 6 cm in maximum diameter in right cardiophrenic angle. B. Right pulmonary arteriogram shows entire structure of giant pulmonary arteriovenous malformation. One feeding artery originated from lateral basal segment branch of right pulmonary artery (A9) (arrow) and another from posterior basal segment branch (A10) (arrowhead). C. Fluoroscopic image of inflated balloon (arrow), second microcatheter (arrowhead) advanced beyond balloon, and multiple platinum microcoils (open arrow) to embolize feeding artery from lateral basal segment branch of right pulmonary artery (A9). D-G. Schemes showing microcoil embolization procedure. First anchored detachable coil (arrow in D) was placed under flow control achieved using balloon (arrowhead in D) without detaching it from delivery wire; multiple microcoils were packed proximally adjacent to first anchored detachable coil using other types of multi-purpose and coaxial catheters (curved arrow in E) by passing balloon. Balloon was then carefully deflated, confirming that no coil migration occurred (F), and finally first anchored detachable coil was detached from delivery wire (G). H. Right pulmonary arteriogram obtained after coil embolization. Note multiple platinum microcoils (arrows) in A9 and A10 feeders. Feeding arteries, nidus, and drainage vein are not visualized. At one year postoperatively, diameter of nidus was reduced to 15 mm.