Literature DB >> 22247500

Accuracy of 6 routine 25-hydroxyvitamin D assays: influence of vitamin D binding protein concentration.

Annemieke C Heijboer1, Marinus A Blankenstein, Ido P Kema, Madelon M Buijs.   

Abstract

BACKGROUND: Recent recognition of its broad pathophysiological importance has triggered an increased interest in 25-hydroxyvitamin D [25(OH)D]. By consequence, throughput in 25(OH)D testing has become an issue for clinical laboratories, and several automated assays for measurement of 25(OH)D are now available. The aim of this study was to test the accuracy and robustness of these assays by comparing their results to those of an isotope dilution/online solid-phase extraction liquid chromatography/tandem mass spectrometry (ID-XLC-MS/MS) method. We put specific focus on the influence of vitamin D-binding protein (DBP) by using samples with various concentrations of DBP.
METHODS: We used 5 automated assays (Architect, Centaur, iSYS, Liaison, and Elecsys), 1 RIA (Diasorin) preceded by extraction, and an ID-XLC-MS/MS method to measure 25(OH)D concentrations in plasma samples of 51 healthy individuals, 52 pregnant women, 50 hemodialysis patients, and 50 intensive care patients. Using ELISA, we also measured DBP concentrations in these samples.
RESULTS: Most of the examined 25(OH)D assays showed significant deviations in 25(OH)D concentrations from those of the ID-XLC-MS/MS method. As expected, DBP concentrations were higher in samples of pregnant women and lower in samples of IC patients compared to healthy controls. In 4 of the 5 fully automated 25(OH)D assays, we observed an inverse relationship between DBP concentrations and deviations from the ID-XLC-MS/MS results.
CONCLUSIONS: 25(OH)D measurements performed with most immunoassays suffer from inaccuracies that are DBP concentration dependent. Therefore, when interpreting results of 25(OH)D measurements, careful consideration of the measurement method is necessary.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22247500     DOI: 10.1373/clinchem.2011.176545

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  96 in total

1.  Medication-related fall incidents in an older, ambulant population: the B-PROOF study.

Authors:  Annelies C Ham; Karin M A Swart; Anke W Enneman; Suzanne C van Dijk; Sadaf Oliai Araghi; Janneke P van Wijngaarden; Nikita L van der Zwaluw; Elske M Brouwer-Brolsma; Rosalie A M Dhonukshe-Rutten; Natasja M van Schoor; Tischa J M van der Cammen; Paul Lips; Lisette C P G M de Groot; André G Uitterlinden; Renger F Witkamp; Bruno H Stricker; Nathalie van der Velde
Journal:  Drugs Aging       Date:  2014-12       Impact factor: 3.923

2.  Standardizing 25-hydroxyvitamin D values from the Canadian Health Measures Survey.

Authors:  Kurtis Sarafin; Ramón Durazo-Arvizu; Lu Tian; Karen W Phinney; Susan Tai; Johanna E Camara; Joyce Merkel; Evan Green; Christopher T Sempos; Stephen P J Brooks
Journal:  Am J Clin Nutr       Date:  2015-09-30       Impact factor: 7.045

3.  Accurate and reliable quantification of 25-hydroxy-vitamin D species by liquid chromatography high-resolution tandem mass spectrometry.

Authors:  Gerhard Liebisch; Silke Matysik
Journal:  J Lipid Res       Date:  2015-04-01       Impact factor: 5.922

4.  Standardization of measurements of 25-hydroxyvitamin D3 and D2.

Authors:  Linda M Thienpont; Hedwig C M Stepman; Hubert W Vesper
Journal:  Scand J Clin Lab Invest Suppl       Date:  2012

Review 5.  Vitamin D assays and the definition of hypovitaminosis D: results from the First International Conference on Controversies in Vitamin D.

Authors:  Christopher T Sempos; Annemieke C Heijboer; Daniel D Bikle; Jens Bollerslev; Roger Bouillon; Patsy M Brannon; Hector F DeLuca; Glenville Jones; Craig F Munns; John P Bilezikian; Andrea Giustina; Neil Binkley
Journal:  Br J Clin Pharmacol       Date:  2018-07-17       Impact factor: 4.335

Review 6.  Analytical considerations for the biochemical assessment of vitamin D status.

Authors:  Lewis Couchman; Cajetan F Moniz
Journal:  Ther Adv Musculoskelet Dis       Date:  2017-02-13       Impact factor: 5.346

7.  Various calibration procedures result in optimal standardization of routinely used 25(OH)D ID-LC-MS/MS methods.

Authors:  Niek F Dirks; Hubert W Vesper; Antonius E van Herwaarden; Jody M W van den Ouweland; Ido P Kema; Johannes G Krabbe; Annemieke C Heijboer
Journal:  Clin Chim Acta       Date:  2016-08-25       Impact factor: 3.786

Review 8.  Vitamin D Status and Supplementation in the Critically Ill.

Authors:  T J McKinney; Jayshil J Patel; Matthew V Benns; Nicholas A Nash; Keith R Miller
Journal:  Curr Gastroenterol Rep       Date:  2016-04

Review 9.  Vitamin D and metabolites measurement by tandem mass spectrometry.

Authors:  Johannes M W van den Ouweland; Michael Vogeser; Silvia Bächer
Journal:  Rev Endocr Metab Disord       Date:  2013-06       Impact factor: 6.514

Review 10.  The use of fibroblast growth factor 23 testing in patients with kidney disease.

Authors:  Edward R Smith
Journal:  Clin J Am Soc Nephrol       Date:  2014-02-27       Impact factor: 8.237

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.