Analysis of post-exposure density growth in radiochromic film with respect to the radiation dose.

Katsumi Shima1, Kunihiko Tateoka, Yuichi Saitoh, Junji Suzuki, Yuji Yaegashi, Kazunori Fujimoto, Takuya Nakazawa, Akihiro Nakata, Tadanori Abe, Sho Imai, Kouichi Sakata, Masato Hareyama.   

Abstract

The post-exposure density growth (PEDG) is one of the characteristics of radiochromic film (RCF). In film dosimetry using RCF and a flatbed scanner, pixel values read out from the RCF are converted to dose (hereafter, film dose) by using a calibration curve. The aim of this study is to analyze the relationship between the pixel value read out from the RCF and the PEDG, and that between the film dose converted from the RCF and the PEDG. The film (GAFCHROMIC EBT) was irradiated with 10-MV X-rays in an ascending 11-dose-step arrangement. The pixel values of the irradiated EBT film were measured at arbitrary hours using an Epson flatbed scanner. In this study, the reference time was 24 h after irradiation, and all dose conversions from the pixel values read out from the EBT film were made using a calibration curve for 24 h after irradiation. For delivered doses of 33 and 348 cGy, the measured pixel values at 0.1 and 16 h after irradiation represented ranges of -9.6% to -0.7% and -3.9% to -0.3%, respectively, of the reference value. The relative changes between the pixel values read out from the EBT film at each elapsed time and that at the reference time decreased with increasing delivered dose. However, the difference range for all the film doses had a width of approximately -10% of the reference value at elapsed times from 0.1 to 16 h, and it showed no dependence on the delivered dose.

Entities:  

Mesh:

Year:  2012        PMID: 22245751     DOI: 10.1269/jrr.11091

Source DB:  PubMed          Journal:  J Radiat Res        ISSN: 0449-3060            Impact factor:   2.724


  3 in total

1.  Characterization of GafChromic EBT2 film dose measurements using a tissue-equivalent water phantom for a Theratron® Equinox Cobalt-60 teletherapy machine.

Authors:  Daniel Akwei Addo; Elsie Effah Kaufmann; Samuel Nii Tagoe; Augustine Kwame Kyere
Journal:  PLoS One       Date:  2022-08-19       Impact factor: 3.752

2.  Three-dimensional radiochromic film dosimetry for volumetric modulated arc therapy using a spiral water phantom.

Authors:  Masao Tanooka; Hiroshi Doi; Hideharu Miura; Hiroyuki Inoue; Yasue Niwa; Yasuhiro Takada; Masayuki Fujiwara; Toshiyuki Sakai; Kiyoshi Sakamoto; Norihiko Kamikonya; Shozo Hirota
Journal:  J Radiat Res       Date:  2013-05-17       Impact factor: 2.724

3.  A method for time-independent film dosimetry: Can we obtain accurate patient-specific QA results at any time postirradiation?

Authors:  Leon Dunn; Guy Godwin; James Hellyer; Xiaolei Xu
Journal:  J Appl Clin Med Phys       Date:  2022-01-20       Impact factor: 2.102

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.