Literature DB >> 22244624

Does a combination of two radiographs increase accuracy in detecting acid-induced periapical lesions and does it approach the accuracy of cone-beam computed tomography scanning?

Elif Soğur1, Hans-Göran Gröndahl, B Güniz Baksı, Ali Mert.   

Abstract

INTRODUCTION: The purpose of this study was to determine whether the use of a combination of 2 images (storage phosphor plates [SPPs] and F-speed films [Eastman Kodak, Rochester, NY]) with a 10° difference in horizontal beam angulation resulted in better detectability of chemically created periapical defects than when only 1 image was used and whether a detectability as good as that achieved by limited cone-beam computed tomography (LCBCT) scanning could be achieved.
METHODS: Lesions were created by 1, 1.5, and 2 hours of acid application apical to extracted teeth in jaw specimens. After repositioning, teeth were radiographed with Accu-I-Tomo LCBCT, Digora Optime SPP system, and F-speed films. The SPPs and films were exposed at 0° and 10° horizontal angulations. The diagnostic accuracy (Az) was compared using 2-way analysis of variance; pair-wise comparisons were performed using the post hoc t test. Kappa was used to measure interobserver agreement.
RESULTS: A combination of 2 exposures with a 10° difference in horizontal angulation caused an increase, although not statistically significant, in the accuracy of both films and SPPs for all acid durations (P > .05) compared with when only 1 exposure was used. The accuracy did not approach that of LCBCT.
CONCLUSIONS: Using a combination of 2 exposures instead of 1 did not significantly increase the accuracy in detecting acid-induced lesions at the apices of single-rooted premolars. The accuracy of LCBCT was superior.
Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22244624     DOI: 10.1016/j.joen.2011.10.013

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  7 in total

Review 1.  [Comparison between cone beam computed tomography and periapical radiography in the diagnosis of periapical disease].

Authors:  Gao Jing; Shen Jing
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2015-04

2.  Comparison of cone-beam computed tomography and periapical radiography in predicting treatment decision for periapical lesions: a clinical study.

Authors:  Ashok Balasundaram; Punit Shah; Michael M Hoen; Michelle A Wheater; Josef S Bringas; Arnold Gartner; James R Geist
Journal:  Int J Dent       Date:  2012-09-30

3.  Accuracy of Periapical Radiography and CBCT in Endodontic Evaluation.

Authors:  R Lo Giudice; F Nicita; F Puleio; A Alibrandi; G Cervino; A S Lizio; G Pantaleo
Journal:  Int J Dent       Date:  2018-10-16

4.  Detection of Simulated Periapical Lesion in Intraoral Digital Radiography with Different Brightness and Contrast.

Authors:  Hugo Gaêta-Araujo; Eduarda Helena Leandro Nascimento; Danieli Moura Brasil; Amanda Farias Gomes; Deborah Queiroz Freitas; Christiano De Oliveira-Santos
Journal:  Eur Endod J       Date:  2019-11-22

5.  Comparative Assessment of the Efficacy of Two-Dimensional Digital Intraoral Radiography to Three-Dimensional Cone Beam Computed Tomography in the Diagnosis of Periapical Pathologies.

Authors:  S Surya; Akash Narayan Dutta Barua; Shaliputra Pralhad Magar; Shilpa Shaliputra Magar; Rathi Rela; Amarpal Kour Chhabada
Journal:  J Pharm Bioallied Sci       Date:  2022-07-13

6.  Accuracy of digital radiography and cone beam computed tomography on periapical radiolucency detection in endodontically treated teeth.

Authors:  Tadas Venskutonis; Povilas Daugela; Marijus Strazdas; Gintaras Juodzbalys
Journal:  J Oral Maxillofac Res       Date:  2014-07-01

7.  Reliability of cone beam computed tomography as a biopsy-independent tool in differential diagnosis of periapical cysts and granulomas: An In vivo Study.

Authors:  Ankit Chanani; Haridas Das Adhikari
Journal:  J Conserv Dent       Date:  2017 Sep-Oct
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.