Literature DB >> 22244611

Results of laser in situ keratomileusis performed using solid-state laser technology.

David P Piñero1, Rafael J Pérez-Cambrodí, Aránzazu Gómez-Hurtado, Francisco J Blanes-Mompó, Antonio Alzamora-Rodríguez.   

Abstract

PURPOSE: To evaluate and report the visual, refractive, and aberrometry outcomes of laser in situ keratomileusis (LASIK) to correct low to moderate myopia using a commercial solid-state laser.
SETTING: Oftalmar, Medimar International Hospital, Alicante, Spain.
DESIGN: Prospective case series.
METHODS: This study evaluated consecutive eyes with low to moderate myopia that had LASIK performed using a Pulzar Z1 solid-state laser. Visual, refractive, and aberrometry changes as well as potential complications were evaluated.
RESULTS: The study enrolled 60 eyes (34 patients). The mean follow-up was 8.5 months (range 6 to 13 months). There was a significant improvement in logMAR uncorrected distance visual acuity (UDVA) postoperatively (P<.01). No significant change was detected in logMAR corrected distance visual acuity (CDVA) (P=.21). The postoperative logMAR UDVA was 0.1 (approximately 20/25) or better in 57 eyes (95.00%). The mean overall efficacy index was 0.99 and the mean safety index, 1.02. Postoperatively, 1 eye (1.67%) lost lines (1 line) of CDVA. The postoperative spherical equivalent was within ± 0.50 diopter in 58 eyes (96.67%). There was a small, but statistically significant increase in the primary coma root mean square (0.17 μm) and in the magnitude of primary spherical aberration (0.09 μm). No severe complications occurred.
CONCLUSION: Laser in situ keratomileusis using the solid-state laser provided predictable correction of low to moderate myopia, minimizing the induction of higher-order aberrations and preserving CDVA. FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.
Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22244611     DOI: 10.1016/j.jcrs.2011.09.038

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  1 in total

1.  Pilot study of hyperopic LASIK using the solid-state laser technology.

Authors:  David P Piñero; Francisco J Blanes-Mompó; Pedro Ruiz-Fortes; Rafael J Pérez-Cambrodí; Antonio Alzamora-Rodríguez
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-10-05       Impact factor: 3.117

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.