Literature DB >> 22244562

Impairment of pericardial leaflet structure from balloon-expanded valved stents.

Wiebke de Buhr1, Stefan Pfeifer, Julia Slotta-Huspenina, Erich Wintermantel, Georg Lutter, Wolfgang A Goetz.   

Abstract

OBJECTIVE: Malpositioning is one of the major problems in transcatheter aortic valve implantation. To evaluate the influence of mechanical balloon inflation on aortic valve stent positioning, the expansion process and the impact on the valve leaflet's structure were investigated.
METHODS: Custom-made stents were laser cut from a 22-mm diameter stainless steel tube and mounted with a glutaraldehyde-treated bovine pericardial valve. The valved stents were crimped onto a standard balloon catheter and expanded by inflation of the balloon with 2 bar for 3 seconds. Expansion was studied using a high-speed camera, and the histology of the pericardial tissue was analyzed.
RESULTS: The valved stents were fully expanded within 3 seconds. Balloon inflation was observed to be asymmetric starting proximally. At the beginning of expansion, the valved stents were pulled proximally. During further inflation, the stents slipped distally on the balloon and experienced a total displacement of 13.5 mm. Macroscopic examination showed severe imprinting of the stent struts into the pericardial tissue. Histology revealed disrupted tissue layers and collagen fibers.
CONCLUSIONS: Analysis of valved stent expansion showed a displacement of the stent on the catheter during balloon inflation. Therefore, precise placement of the valved stent cannot be accomplished. Histologic analysis of the expanded pericardial tissue revealed disruption of collagen fibers. Disruption of pericardial tissue structures due to balloon expansion may result in early functional valve failure.
Copyright © 2012 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22244562     DOI: 10.1016/j.jtcvs.2011.11.001

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  9 in total

1.  Physical Characterization and Platelet Interactions under Shear Flows of a Novel Thermoset Polyisobutylene-based Co-polymer.

Authors:  Jawaad Sheriff; Thomas E Claiborne; Phat L Tran; Roshni Kothadia; Sheela George; Yasushi P Kato; Leonard Pinchuk; Marvin J Slepian; Danny Bluestein
Journal:  ACS Appl Mater Interfaces       Date:  2015-09-23       Impact factor: 9.229

Review 2.  On the Mechanics of Transcatheter Aortic Valve Replacement.

Authors:  Lakshmi P Dasi; Hoda Hatoum; Arash Kheradvar; Ramin Zareian; S Hamed Alavi; Wei Sun; Caitlin Martin; Thuy Pham; Qian Wang; Prem A Midha; Vrishank Raghav; Ajit P Yoganathan
Journal:  Ann Biomed Eng       Date:  2016-11-21       Impact factor: 3.934

Review 3.  Principles of TAVR valve design, modelling, and testing.

Authors:  Oren M Rotman; Matteo Bianchi; Ram P Ghosh; Brandon Kovarovic; Danny Bluestein
Journal:  Expert Rev Med Devices       Date:  2018-10-29       Impact factor: 3.166

4.  Leaflet thrombosis after valve-in-valve transcatheter aortic valve implantation: a case series.

Authors:  Dincer Aktuerk; Saeed Mirsadraee; Cesare Quarto; Simon Davies; Alison Duncan
Journal:  Eur Heart J Case Rep       Date:  2020-09-16

Review 5.  Polymeric trileaflet prosthetic heart valves: evolution and path to clinical reality.

Authors:  Thomas E Claiborne; Marvin J Slepian; Syed Hossainy; Danny Bluestein
Journal:  Expert Rev Med Devices       Date:  2012-11       Impact factor: 3.166

6.  In vitro evaluation of a novel hemodynamically optimized trileaflet polymeric prosthetic heart valve.

Authors:  Thomas E Claiborne; Jawaad Sheriff; Maximilian Kuetting; Ulrich Steinseifer; Marvin J Slepian; Danny Bluestein
Journal:  J Biomech Eng       Date:  2013-02       Impact factor: 2.097

7.  Toward optimization of a novel trileaflet polymeric prosthetic heart valve via device thrombogenicity emulation.

Authors:  Thomas E Claiborne; Michalis Xenos; Jawaad Sheriff; Wei-Che Chiu; Joao Soares; Yared Alemu; Shikha Gupta; Stefan Judex; Marvin J Slepian; Danny Bluestein
Journal:  ASAIO J       Date:  2013 May-Jun       Impact factor: 2.872

8.  In Vitro Durability and Stability Testing of a Novel Polymeric Transcatheter Aortic Valve.

Authors:  Oren M Rotman; Brandon Kovarovic; Matteo Bianchi; Marvin J Slepian; Danny Bluestein
Journal:  ASAIO J       Date:  2020-02       Impact factor: 3.826

9.  In Vitro Hydrodynamic Assessment of a New Transcatheter Heart Valve Concept (the TRISKELE).

Authors:  Benyamin Rahmani; Spyros Tzamtzis; Rose Sheridan; Michael J Mullen; John Yap; Alexander M Seifalian; Gaetano Burriesci
Journal:  J Cardiovasc Transl Res       Date:  2016-12-27       Impact factor: 4.132

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.