Herein, ultrasound-assisted emulsification microextraction (USAEME) and dispersive liquid-liquid microextraction (DLLME) methods based on applying low-density organic solvents have been critically compared for the speciation of inorganic selenium, Se(IV) (selenite) and Se(VI) (selenate) in environmental water samples by gas chromatography-flame ionization detection (GC-FID). At pH 2 and T=75°C for 7 min, only Se(IV) was able to form the piazselenol complex with 4-nitro-o-phenylenediamine. Piazselenol was extracted using an extraction solvent and was injected into a GC-FID instrument for the determination of Se(IV). Conveniently, Se(VI) remained in the aqueous phase. Total inorganic selenium was determined after the reduction of Se(VI) to Se(IV) and prior to the above procedures. The Se(VI) concentration was calculated as the difference between the measured total inorganic selenium and Se(IV) content. The effect of various experimental parameters on the efficiencies of the two methods and their optimum values were studied with the aid of response surface methodology and experimental design. Under the optimal conditions, the limit of detections (LODs) for Se(IV) obtained by USAEME-GC-FID and DLLME-GC-FID were 0.05 and 0.11 ng mL(-1), respectively. The relative standard deviations (RSDs, n=6) for the measurement 10 ng mL(-1) of Se(IV) were 5.32% and 4.57% with the enrichment factors of 2491 and 1129 for USAEME-GC-FID and DLLME-GC-FID, respectively. Both methods were successfully applied to the analysis of inorganic selenium in different environmental water samples and certified reference material (NIST SRM 1643e).
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22244140     DOI: 10.1016/j.aca.2011.11.063

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  3 in total

1.  Optimization of the extraction of total flavonoids from Scutellaria baicalensis Georgi using the response surface methodology.

Authors:  Yanqing Liu; Hongwu Wang; Xuan Cai
Journal:  J Food Sci Technol       Date:  2014-03-01       Impact factor: 2.701

2.  Voltammetric and impedimetric determinations of selenium(iv) by an innovative gold-free poly(1-aminoanthraquinone)/multiwall carbon nanotube-modified carbon paste electrode.

Authors:  Asmaa Galal Ali; Mahmoud Fatehy Altahan; Amr Mohamed Beltagi; Abla Ahmed Hathoot; Magdi Abdel-Azzem
Journal:  RSC Adv       Date:  2022-02-10       Impact factor: 3.361

3.  Determination of phenols and pharmaceuticals in municipal wastewaters from Polish treatment plants by ultrasound-assisted emulsification-microextraction followed by GC-MS.

Authors:  Urszula Kotowska; Justyna Kapelewska; Joanna Sturgulewska
Journal:  Environ Sci Pollut Res Int       Date:  2013-07-02       Impact factor: 4.223

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.