Literature DB >> 22241011

A comparison of intrascleral bleb height by anterior segment OCT using three different implants in deep sclerectomy.

R Fernández-Buenaga1, G Rebolleda, P Casas-Llera, F J Muñoz-Negrete, M Pérez-López.   

Abstract

PURPOSE: To compare intrascleral blebs characteristics after deep sclerectomy (DS) with three intrascleral implants using the Visante anterior segment optical coherence tomography.
METHODS: This is a cross-sectional study including 60 eyes of 51 patients that underwent DS with Sk-Gel, Esnoper, and Aquaflow implant. Intraocular pressure (IOP) measurement, slit-lamp examination, and Visante scans were performed the same day in all the patients. Visante scans were done through the intrascleral bleb at 45°, 90°, and 135° and the bleb height was measured.
RESULTS: Sk-Gel was used in 19 eyes (31.66%), Esnoper in 22 eyes (36.66%), and Aquaflow in 19 eyes (31.66%). The median time lapsed from the surgery was 15.50 months 25th and 75th percentiles (p(25) 8.25; p(75) 20). The median IOP was 13 mm Hg (p(25) 10; p(75) 15), with no significant differences among implants (P = 0.232). Overall, the correlation between the scleral bleb height and the IOP was statistically significant at 45° (r=-0.359; P = 0.004), 90° (r = -0.410; P = 0.001), and 135° (r = -0.417; P = 0.001). However, Sk-Gel did not show any statistically significant correlation between the scleral height and IOP whereas the other two groups (Esnoper and Aquaflow) showed a significant correlation. There were no differences in the bleb height among implants.
CONCLUSION: There was a moderate inverse correlation between the scleral bleb height and the IOP measurement after DS with Esnoper and Aquaflow implants. There were no differences in bleb height among the three implants.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22241011      PMCID: PMC3325577          DOI: 10.1038/eye.2011.358

Source DB:  PubMed          Journal:  Eye (Lond)        ISSN: 0950-222X            Impact factor:   3.775


  19 in total

Review 1.  How does nonpenetrating glaucoma surgery work? Aqueous outflow resistance and glaucoma surgery.

Authors:  D H Johnson; M Johnson
Journal:  J Glaucoma       Date:  2001-02       Impact factor: 2.503

2.  An ultrasound biomicroscopy study of filtering blebs after deep sclerectomy with a new acrylic implant.

Authors:  Laura Cabrejas; Gema Rebolleda; Francisco José Muñoz-Negrete; Diego Losada
Journal:  Eur J Ophthalmol       Date:  2011 Jul-Aug       Impact factor: 2.597

3.  A pilot study of a system for grading of drainage blebs after glaucoma surgery.

Authors:  A P Wells; J G Crowston; J Marks; J F Kirwan; G Smith; J C K Clarke; R Shah; J Vieira; C Bunce; I Murdoch; P T Khaw
Journal:  J Glaucoma       Date:  2004-12       Impact factor: 2.503

4.  Filtering bleb evaluation with slit-lamp-adapted 1310-nm optical coherence tomography.

Authors:  Maya Müller; Hans Hoerauf; Gerd Geerling; Stefanie Pape; Christian Winter; Gereon Hüttmann; Reginald Birngruber; Horst Laqua
Journal:  Curr Eye Res       Date:  2006-11       Impact factor: 2.424

Review 5.  Recent advances in ophthalmic anterior segment imaging: a new era for ophthalmic diagnosis?

Authors:  Aristides Konstantopoulos; Parwez Hossain; David F Anderson
Journal:  Br J Ophthalmol       Date:  2007-04       Impact factor: 4.638

6.  Imaging of trabeculectomy blebs using anterior segment optical coherence tomography.

Authors:  Mandeep Singh; Paul T K Chew; David S Friedman; Winifred P Nolan; Jovina L See; Scott D Smith; Ce Zheng; Paul J Foster; Tin Aung
Journal:  Ophthalmology       Date:  2006-10-27       Impact factor: 12.079

7.  Morphologic classification of filtering blebs after glaucoma filtration surgery: the Indiana Bleb Appearance Grading Scale.

Authors:  Louis B Cantor; Anand Mantravadi; Darrell WuDunn; Kala Swamynathan; Arnold Cortes
Journal:  J Glaucoma       Date:  2003-06       Impact factor: 2.503

Review 8.  [Glaucoma and ultrasound biomicroscopy].

Authors:  E Blumen-Ohana; N Hamelin; J-P Nordmann
Journal:  J Fr Ophtalmol       Date:  2004-05       Impact factor: 0.818

9.  Comparative study between deep sclerectomy with and without collagen implant: long term follow up.

Authors:  T Shaarawy; C Nguyen; C Schnyder; A Mermoud
Journal:  Br J Ophthalmol       Date:  2004-01       Impact factor: 4.638

View more
  6 in total

1.  Effect of filtering bleb dimensions on postoperative intraocular pressure in deep sclerectomy with collagen implant: a comparative study.

Authors:  Hany Elmekawey; Ahmed Abdelrahman; Mohamad S Kotb; Diia Alden Mostafa
Journal:  Int Ophthalmol       Date:  2019-07-18       Impact factor: 2.031

2.  Long-term outcomes of needle revision of failing deep sclerectomy blebs.

Authors:  Antigoni Koukkoulli; Fayyaz Musa; Nitin Anand
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-10-11       Impact factor: 3.117

3.  Deep Sclerectomy With a New Nonabsorbable Uveoscleral Implant (Esnoper-Clip): 1-Year Outcomes.

Authors:  Jordi Loscos-Arenas; Angels Parera-Arranz; Pau Romera-Romera; Jordi Castellvi-Manent; Antoni Sabala-Llopart; Julio de la Cámara-Hermoso
Journal:  J Glaucoma       Date:  2015-08       Impact factor: 2.503

4.  Biodegradable PTLGA Terpolymers versus Collagen Implants Used as an Adjuvant in Trabeculectomy in Rabbit Eye.

Authors:  Weiran Niu; Guanglin Shen; Yuanzhi Yuan; Xiaoping Ma; Suming Li; Jingzhao Wang; Zhongyong Fan; Lan Liao
Journal:  J Ophthalmol       Date:  2015-11-30       Impact factor: 1.909

Review 5.  Anterior Segment Optical Coherence Tomography Imaging of Filtering Blebs after Deep Sclerectomy with Esnoper-Clip Implant: One-year Follow-up.

Authors:  Luisa Vieira; Manuel Noronha; Vanessa Lemos; Maria Reina; Teresa Gomes
Journal:  J Curr Glaucoma Pract       Date:  2015-01-15

6.  The CLASS Surgical Site Characteristics in a Clinical Grading Scale and Anterior Segment Optical Coherence Tomography: A One-Year Follow-Up.

Authors:  Judyta Jankowska-Szmul; Edward Wylegala
Journal:  J Healthc Eng       Date:  2018-05-15       Impact factor: 2.682

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.