Literature DB >> 22235792

Conventional multi-slice computed tomography (CT) and cone-beam CT (CBCT) for computer-aided implant placement. Part II: reliability of mucosa-supported stereolithographic guides.

Volkan Arisan1, Zihni Cüneyt Karabuda, Bülent Pişkin, Tayfun Özdemir.   

Abstract

PURPOSE: Deviations of implants that were placed by conventional computed tomography (CT)- or cone beam CT (CBCT)-derived mucosa-supported stereolithographic (SLA) surgical guides were analyzed in this study.
MATERIALS AND METHODS: Eleven patients were randomly scanned by a multi-slice CT (CT group) or a CBCT scanner (CBCT group). A total of 108 implants were planned on the software and placed using SLA guides. A new CT or CBCT scan was obtained and merged with the planning data to identify the deviations between the planned and placed implants. Results were analyzed by Mann-Whitney U test and multiple regressions (p < .05).
RESULTS: Mean angular and linear deviations in the CT group were 3.30° (SD 0.36), and 0.75 (SD 0.32) and 0.80 mm (SD 0.35) at the implant shoulder and tip, respectively. In the CBCT group, mean angular and linear deviations were 3.47° (SD 0.37), and 0.81 (SD 0.32) and 0.87 mm (SD 0.32) at the implant shoulder and tip, respectively. No statistically significant differences were detected between the CT and CBCT groups (p = .169 and p = .551, p = .113 for angular and linear deviations, respectively).
CONCLUSIONS: Implant placement via CT- or CBCT-derived mucosa-supported SLA guides yielded similar deviation values. Results should be confirmed on alternative CBCT scanners.
© 2012 Wiley Periodicals, Inc.

Entities:  

Keywords:  computed tomography; computer assisted; cone beam; dental implants; deviation from the planning; gray density; stereolithography

Mesh:

Substances:

Year:  2012        PMID: 22235792     DOI: 10.1111/j.1708-8208.2011.00435.x

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  8 in total

1.  CT dataset anisotropy management for oral implantology planning software.

Authors:  Tommaso Chiarelli; Evelina Lamma; Tommaso Sansoni
Journal:  Int J Comput Assist Radiol Surg       Date:  2012-06-17       Impact factor: 2.924

2.  [Research advances in the use of digital surgical guides in implantology].

Authors:  Xiao-Hua Wang; Ai-Peng Liu; Wen-Zheng Deng
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2020-02-01

3.  Computer-assisted flapless implant placement reduces the incidence of surgery-related bacteremia.

Authors:  Volkan Arısan; Nilüfer Bölükbaşı; Lütfiye Öksüz
Journal:  Clin Oral Investig       Date:  2012-12-06       Impact factor: 3.573

4.  Alveolar ridge preservation and primary stability as influencing factors on the transfer accuracy of static guided implant placement: a prospective clinical trial.

Authors:  Sigmar Schnutenhaus; Liesa Brunken; Cornelia Edelmann; Jens Dreyhaupt; Heike Rudolph; Ralph G Luthardt
Journal:  BMC Oral Health       Date:  2020-06-29       Impact factor: 2.757

Review 5.  Role of three-dimensional printing in periodontal regeneration and repair: Literature review.

Authors:  Meisha Gul; Aysha Arif; Robia Ghafoor
Journal:  J Indian Soc Periodontol       Date:  2019 Nov-Dec

6.  Accuracy of Guided Implant Surgery in the Edentulous Jaw Using Desktop 3D-Printed Mucosal Supported Guides.

Authors:  Rani D'haese; Tom Vrombaut; Geert Hommez; Hugo De Bruyn; Stefan Vandeweghe
Journal:  J Clin Med       Date:  2021-01-20       Impact factor: 4.241

Review 7.  Accuracy of Computer-Assisted Flapless Implant Placement by Means of Mucosa-Supported Templates in Complete-Arch Restorations: A Systematic Review.

Authors:  Paolo Carosi; Claudia Lorenzi; Fabrizio Lio; Pierluigi Cardelli; Alessandro Pinto; Andrea Laureti; Alessandro Pozzi
Journal:  Materials (Basel)       Date:  2022-02-16       Impact factor: 3.623

8.  Accuracy of implant surgical guides fabricated using computer numerical control milling for edentulous jaws: a pilot clinical trial.

Authors:  Jinyou Chai; Xiaoqian Liu; Ramona Schweyen; Jürgen Setz; Shaoxia Pan; Jianzhang Liu; Yongsheng Zhou
Journal:  BMC Oral Health       Date:  2020-10-21       Impact factor: 2.757

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.