Literature DB >> 22234753

Comparison of 19- and 22-gauge needles in EUS-guided fine needle aspiration in patients with mediastinal masses and lymph nodes.

Necla Songür1, Yıldıran Songür, Sema Bırcan, Nilgün Kapucuoğlu.   

Abstract

BACKGROUND/AIMS: Endoscopic ultrasound-guided fine needle aspiration is an established tissue-acquisition technique for mediastinal lesions. However, there are limitations to endoscopic ultrasound-guided fine needle aspiration of mediastinal masses in certain neoplasms and granulomatous diseases. Most studies have used 22-gauge aspiration and/or 19-gauge Tru-cut needles, and only limited data exist on larger-caliber aspiration needles. We aimed to compare prospectively the diagnostic yield of endoscopic ultrasound-guided fine needle aspiration using 19- and 22-gauge aspiration needles in patients with mediastinal lesions of unknown origin.
MATERIAL AND METHODS: Using a consecutive entry design, 57 patients with mediastinal mass or lymph node, in whom previous investigations, including bronchoscopy and computed tomography-guided biopsy, had not provided a final diagnosis, underwent endoscopic ultrasound-guided fine needle aspiration biopsy using 19-gauge or 22-gauge aspiration needle. Determination of the adequacy and cytopathologic interpretation of fine needle aspiration materials were done by two pathologists blinded to the clinical condition of the patient. Fine needle aspiration specimens were placed in four categories as: (1) nondiagnostic, (2) benign, (3) granulomatous disease, and (4) malignant.
RESULTS: Among 57 patients [35 (61.4%) with mediastinal lymph nodes and 22 (38.5%) with pulmonary masses], adequate tissue was obtained in 52 (91.2%) of the cases (with a mean of 3.3 needle passes). Correct cytopathologic diagnoses were made based on the endoscopic ultrasound-guided fine needle aspiration specimens obtained by 19- and 22-gauge needles in 96% and 92% of the samples, respectively (p>0.05).
CONCLUSIONS: As concerns endoscopic ultrasound-guided fine needle aspiration of mediastinal masses and lymph nodes, the diagnostic sensitivity of aspirated material obtained using 19- and 22-gauge fine needle aspiration needles was found to be comparable in our study.

Entities:  

Mesh:

Year:  2011        PMID: 22234753     DOI: 10.4318/tjg.2011.0322

Source DB:  PubMed          Journal:  Turk J Gastroenterol        ISSN: 1300-4948            Impact factor:   1.852


  4 in total

Review 1.  Esophageal Endosonography for the Diagnosis of Intrapulmonary Tumors: A Systematic Review and Meta-Analysis.

Authors:  Daniël A Korevaar; Sara Colella; René Spijker; Patrick M Bossuyt; Lars Konge; Paul Frost Clementsen; Jouke T Annema
Journal:  Respiration       Date:  2016-12-08       Impact factor: 3.580

2.  Pathologic evaluation of a new endoscopic ultrasound needle designed to obtain core tissue samples: A pilot study.

Authors:  Douglas G Adler; Benjamin Witt; Barbara Chadwick; Jason Wells; Linda Jo Taylor; Christopher Dimaio; Robert Schmidt
Journal:  Endosc Ultrasound       Date:  2016 May-Jun       Impact factor: 5.628

Review 3.  "Clinical" cytology for endoscopists: A practical guide.

Authors:  Michael Hocke; Theodoros Topalidis; Barbara Braden; Christoph F Dietrich
Journal:  Endosc Ultrasound       Date:  2017 Mar-Apr       Impact factor: 5.628

4.  Evaluation of the SharkCore® needle for EUS-guided core biopsy of pancreatic neuroendocrine tumors.

Authors:  Benjamin L Witt; Rachel E Factor; Barbara E Chadwick; Justin Caron; Ali A Siddiqui; Douglas G Adler
Journal:  Endosc Ultrasound       Date:  2018 Sep-Oct       Impact factor: 5.628

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.