Literature DB >> 22230912

The effect of multiple firings on the marginal integrity of pressable ceramic single crowns.

Seok-Hwan Cho1, William W Nagy, John T Goodman, Eric Solomon, Mari Koike.   

Abstract

STATEMENT OF PROBLEM: The marginal adaptation of metal ceramic crowns is affected by firing cycles for veneering porcelain application. The effect of multiple firings on the marginal integrity of pressable ceramic core crowns is unknown.
PURPOSE: The purpose of this in vitro study was to evaluate the effect of repeated firing cycles on the marginal discrepancy of veneered (layered) pressable ceramic anterior crowns with 2 different finish line configurations.
MATERIAL AND METHODS: Forty pressable ceramic single anterior complete crowns were fabricated from 2 systems (IPS Empress Esthetic and IPS e.max Press) with 2 finish line designs (shoulder, chamfer) on epoxy resin dies. Specimens were divided into 4 groups of 10, and measurements were made after pressing (control) and after 5 veneer firing stages: 1) wash, 2) first incisal, 3) second incisal, 4) characterization and glazing, and 5) corrective. The change in vertical marginal discrepancy was measured with a light microscope at 4 locations: facial (F), mesial (M), lingual (L), and distal (D) surfaces. One-way ANOVA (α-=.05) was used to evaluate the marginal change. A Student-Newman-Keuls test was also used for comparison among the groups.
RESULTS: There were no significant changes in the vertical marginal integrity related to ceramic type and marginal location and their interactions. However, there was a significant marginal integrity change during the characterization and glazing firing stage. (P<.05)
CONCLUSIONS: The marginal gap increased for both systems during veneer application and decreased during the characterization and glazing firing cycle. The total marginal fit change after 5 firings was 0.33 μm for IPS e.max Press, and 0.27 μm for IPS Empress Esthetic.
Copyright © 2012 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22230912     DOI: 10.1016/S0022-3913(12)60011-0

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  6 in total

1.  The effect of various veneering techniques on the marginal fit of zirconia copings.

Authors:  Kianoosh Torabi; Mahroo Vojdani; Rashin Giti; Masumeh Taghva; Soheil Pardis
Journal:  J Adv Prosthodont       Date:  2015-06-23       Impact factor: 1.904

2.  The zirconia ceramic: strengths and weaknesses.

Authors:  Elie E Daou
Journal:  Open Dent J       Date:  2014-04-18

Review 3.  Fit of tooth-supported zirconia single crowns-A systematic review of the literature.

Authors:  Walaa Magdy Ahmed; Batoul Shariati; Arwa Z Gazzaz; Mohammed E Sayed; Ricardo M Carvalho
Journal:  Clin Exp Dent Res       Date:  2020-09-03

4.  In Vitro Comparison of Marginal and Internal Fit of Zirconia Copings Fabricated by One CAD/CAM System with Two Different Scanners.

Authors:  Zahra Khamverdi; Elmira Najafrad; Maryam Farhadian
Journal:  Front Dent       Date:  2021-01-20

5.  The Use of the Digital Smile Design Concept as an Auxiliary Tool in Aesthetic Rehabilitation: A Case Report.

Authors:  Piero Rocha Zanardi; Raquel Laia Rocha Zanardi; Roberto Chaib Stegun; Newton Sesma; Bru-No Costa; Dalva Cruz Laganá
Journal:  Open Dent J       Date:  2016-02-29

6.  In Vitro Effect of Porcelain Firing Cycle and Different Thicknesses of IPS E.max CAD Core on Marginal Accuracy of All-Ceramic Restorations.

Authors:  Ezatollah Jalalian; Arash Zarbakhsh; Zahra Mohtashamrad; Nazanin Nourbakhsh; Esmat Jafarpour
Journal:  J Dent (Tehran)       Date:  2015-11
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.