Literature DB >> 22229954

Paramedic King Laryngeal Tube airway insertion versus endotracheal intubation in simulated pediatric respiratory arrest.

Michael S Mitchell1, Marjorie Lee White, William D King, Henry E Wang.   

Abstract

INTRODUCTION: Pediatric endotracheal intubation (ETI) is difficult and can have serious adverse events when performed by paramedics in the prehospital setting. Paramedics may use the King Laryngeal Tube airway (KLT) in difficult adult airways, but only limited data describe their application in pediatric patients.
OBJECTIVE: To compare paramedic airway insertion speed and complications between KLT and ETI in a simulated model of pediatric respiratory arrest.
METHODS: This prospective, randomized trial included paramedics and senior paramedic students with limited prior KLT experience. We provided brief training on pediatric KLT insertion. Using a random allocation protocol, participants performed both ETI and KLT on a pediatric mannequin (6-month old size) in simulated respiratory arrest. The primary outcomes were 1) elapsed time to successful airway placement (seconds), and 2) proper airway positioning. We compared airway insertion performance between KLT and ETI using the Wilcoxon signed-ranks test. Subjects also indicated their preferred airway device.
RESULTS: The 25 subjects included 19 paramedics and 6 senior paramedic students. Two subjects had prior adult KLT experience. Airway insertion time was not statistically different between the KLT (median 27 secs) and ETI (median 31 secs) (p = 0.08). Esophageal intubation occurred in 2 of 25 (8%) ETI. Airway leak occurred in 3 of 25 (12%) KLT, but ventilation remained satisfactory. Eighty-four percent of the subjects preferred the KLT over ETI.
CONCLUSIONS: Paramedics and paramedic students demonstrated similar airway insertion performance between KLT and ETI in simulated, pediatric respiratory arrest. Most subjects preferred KLT. KLT may provide a viable alternative to ETI in prehospital pediatric airway management.

Entities:  

Mesh:

Year:  2012        PMID: 22229954     DOI: 10.3109/10903127.2011.640762

Source DB:  PubMed          Journal:  Prehosp Emerg Care        ISSN: 1090-3127            Impact factor:   3.077


  4 in total

1.  Effect of the laryngeal tube on the no-flow-time in a simulated two rescuer basic life support setting with inexperienced users.

Authors:  J Schröder; M Bucher; O Meyer
Journal:  Med Klin Intensivmed Notfmed       Date:  2015-09-15       Impact factor: 0.840

Review 2.  Mapping the use of simulation in prehospital care - a literature review.

Authors:  Anna Abelsson; Ingrid Rystedt; Björn-Ove Suserud; Lillemor Lindwall
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2014-03-28       Impact factor: 2.953

3.  Patient safety events in out-of-hospital paediatric airway management: a medical record review by the CSI-EMS.

Authors:  Matthew Hansen; Garth Meckler; William Lambert; Caitlin Dickinson; Kathryn Dickinson; Joshua Van Otterloo; Jeanne-Marie Guise
Journal:  BMJ Open       Date:  2016-11-11       Impact factor: 2.692

4.  Advances in prehospital airway management.

Authors:  Pe Jacobs; A Grabinsky
Journal:  Int J Crit Illn Inj Sci       Date:  2014-01
  4 in total