Femoral neck fracture following hardware removal.

James A Shaer1, Barbara M Hileman, Jill E Newcomer, Marina C Hanes.   

Abstract

It is uncommon for femoral neck fractures to occur after proximal femoral hardware removal because age, osteoporosis, and technical error are often noted as the causes for this type of fracture. However, excessive alcohol consumption and failure to comply with protected weight bearing for 6 weeks increases the risk of femoral neck fractures.This article describes a case of a 57-year-old man with a high-energy ipsilateral inter-trochanteric hip fracture, comminuted distal third femoral shaft fracture, and displaced lateral tibial plateau fracture. Cephalomedullary fixation was used to fix the ipsilateral femur fractures after medical stabilization and evaluation of the patient. The patient healed clinically and radiographically at 6 months. Despite conservative treatment for painful proximal hardware, elective hip screw removal was performed 22.5 months after injury. Seven weeks later, he sustained a nontraumatic femoral neck fracture.In this case, it is unlikely that the femoral neck fracture occurred as a result of hardware removal. We assumed that, in addition to the patient's alcohol abuse and tobacco use, stress fractures may have attributed to the femoral neck fracture. We recommend using a shorter hip screw to minimize hardware prominence or possibly off-label use of an injectable bone filler, such as calcium phosphate cement. Copyright 2012, SLACK Incorporated.

Entities:  

Mesh:

Year:  2012        PMID: 22229620     DOI: 10.3928/01477447-20111122-34

Source DB:  PubMed          Journal:  Orthopedics        ISSN: 0147-7447            Impact factor:   1.390


  3 in total

1.  A Novel Surgical Technique for Removing Buried Cannulated Screws Using a Guidewire and Countersink: A Report of Two Cases.

Authors:  Yongsheng Chen; Krishna Prasad Giri; Christopher Jon Pearce
Journal:  Open Orthop J       Date:  2015-06-26

2.  Should cannulated screws be removed after a femoral neck fracture has healed, and how? A finite element analysis of the femur before and after cannulated screw removal.

Authors:  Le Wu; Jun Sun; Nan Fang; Qing Peng; Shuo Gao; Lifeng Liu
Journal:  Int Orthop       Date:  2022-07-19       Impact factor: 3.479

3.  Management of Lateral Thigh Pain following Cephalomedullary Nail: A Technical Note.

Authors:  Michael Rosen; Connor Kasik; Michael Swords
Journal:  Spartan Med Res J       Date:  2020-06-08
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.