Literature DB >> 22228850

In vitro comparison of three techniques for ventriculo-aortic junction annuloplasty.

Laurent de Kerchove1, Riccardo Vismara, Andrea Mangini, Gianfranco Beniamino Fiore, Joel Price, Philippe Noirhomme, Carlo Antona, Gebrine El Khoury.   

Abstract

OBJECTIVES: In aortic valve repair, reduction and stabilization of the ventriculo-aortic junction (VAJ) is generally recommended. In this in vitro study, we compare three techniques of annuloplasty: the subcommissural annuloplasty (SCA), the internal ring (IR) and the external ring (ER) annuloplasty.
METHODS: Ten fresh porcine aortic valve preparations were tested in a pulsatile mock loop. Each sample was tested untreated (baseline: B). The annuloplasty techniques were then performed successively in each sample. Each technique was tested, then removed and the following technique performed. SCA was applied at 50% of interleaflet triangle height; the ER and IR were applied with a moderate reduction (15-20%) of the VAJ. Hydrodynamic, video and echographic parameters were collected. Flow rate and arterial pressure were maintained consistently between groups.
RESULTS: Effective orifice area decreased significantly with each annuloplasty technique compared with baseline (P < 0.001). Mean transvalvular pressure drop was significantly higher in the ER and IR vs SCA (P = 0.007). Annuloplasty reduced valve opening and closing time in comparison to baseline. Echocardiography confirmed that the VAJ experienced a greater reduction with the ER and IR vs SCA. A narrowing of the lower third of the sinuses of Valsalva was observed after the ER, and subvalvular narrowing was observed after the IR. Valve coaptation increased with all annuloplasty techniques.
CONCLUSIONS: The three annuloplasty techniques examined demonstrated differential effects on aortic valve function and root morphology. The ER and IR have greater potential to reduce VAJ diameter in comparison to SCA. The IR induced a subvalvular remodelling of the VAJ, whereas the ER induced a paravalvular remodelling.

Entities:  

Mesh:

Year:  2012        PMID: 22228850     DOI: 10.1093/ejcts/ezr237

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  9 in total

Review 1.  Annular management during aortic valve repair: a systematic review.

Authors:  Takashi Kunihara
Journal:  Gen Thorac Cardiovasc Surg       Date:  2015-11-25

2.  Valve sparing root replacement: the remodeling technique with external ring annuloplasty.

Authors:  Emmanuel Lansac; Isabelle Di Centa; Jan Vojacek; Jan Nijs; Jaroslav Hlubocky; Gianclaudio Mecozzi; Mathieu Debauchez
Journal:  Ann Cardiothorac Surg       Date:  2013-01

3.  Anatomy and pathophysiology of the ventriculo-aortic junction: implication in aortic valve repair surgery.

Authors:  Laurent de Kerchove; Gebrine El Khoury
Journal:  Ann Cardiothorac Surg       Date:  2013-01

Review 4.  Aortic valve repair update.

Authors:  Tatsuhiko Komiya
Journal:  Gen Thorac Cardiovasc Surg       Date:  2015-02-05

Review 5.  Aortic valve reimplantation using Kuban Cuff modification in a patient with acute type A aortic dissection and aortic valve insufficiency.

Authors:  Sergey Boldyrev; Vasily Kaleda; Kirill Barbukhatty
Journal:  Ann Cardiothorac Surg       Date:  2016-07

Review 6.  Aortic valve repair: indications and outcomes.

Authors:  Munir Boodhwani; Gebrine El Khoury
Journal:  Curr Cardiol Rep       Date:  2014       Impact factor: 2.931

7.  Comparison of Dacron ring and suture annuloplasty for aortic valve repair-a porcine study.

Authors:  Leila Louise Benhassen; Diana Mathilde Ropcke; Mona Sharghbin; Troels Lading; Jens Kæstel Skov; Marcell Juan Tjørnild; Karen Bagger Poulsen; Tommy Bechsgaard; Søren Nielsen Skov; Sten Lyager Nielsen; John Michael Hasenkam
Journal:  Ann Cardiothorac Surg       Date:  2019-05

8.  Asymmetric Dynamics of the Native Aortic Annulus Evaluated by Force Transducer and Sonomicrometry in a Porcine Model.

Authors:  Leila Louise Benhassen; Diana Mathilde Ropcke; Troels Lading; Jens Kæstel Skov; Tommy Bechsgaard; Søren Nielsen Skov; Sten Lyager Nielsen; John Michael Hasenkam
Journal:  Cardiovasc Eng Technol       Date:  2019-06-07       Impact factor: 2.495

9.  Altered stresses and dynamics after single and double annuloplasty ring for aortic valve repair.

Authors:  Leila Louise Benhassen; Jacob Hesselby Hedensted; Mona Sharghbin; Søren Nielsen Skov; Lisa Carlson Hanse; Marcell Juan Tjørnild; Tommy Bechsgaard; Diana Mathilde Ropcke; Sten Lyager Nielsen; John Michael Hasenkam
Journal:  Eur J Cardiothorac Surg       Date:  2020-06-01       Impact factor: 4.191

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.