Literature DB >> 22226589

An innovative approach of QRS segmentation based on first-derivative, Hilbert and Wavelet Transforms.

João P V Madeiro1, Paulo C Cortez, João A L Marques, Carlos R V Seisdedos, Carlos R M R Sobrinho.   

Abstract

The QRS detection and segmentation processes constitute the first stages of a greater process, e.g., electrocardiogram (ECG) feature extraction. Their accuracy is a prerequisite to a satisfactory performance of the P and T wave segmentation, and also to the reliability of the heart rate variability analysis. This work presents an innovative approach of QRS detection and segmentation and the detailed results of the proposed algorithm based on First-Derivative, Hilbert and Wavelet Transforms, adaptive threshold and an approach of surface indicator. The method combines the adaptive threshold, Hilbert and Wavelet Transforms techniques, avoiding the whole ECG signal preprocessing. After each QRS detection, the computation of an indicator related to the area covered by the QRS complex envelope provides the detection of the QRS onset and offset. The QRS detection proposed technique is evaluated based on the well-known MIT-BIH Arrhythmia and QT databases, obtaining the average sensitivity of 99.15% and the positive predictability of 99.18% for the first database, and 99.75% and 99.65%, respectively, for the second one. The QRS segmentation approach is evaluated on the annotated QT database with the average segmentation errors of 2.85±9.90ms and 2.83±12.26ms for QRS onset and offset, respectively. Those results demonstrate the accuracy of the developed algorithm for a wide variety of QRS morphology and the adaptation of the algorithm parameters to the existing QRS morphological variations within a single record.
Copyright © 2011 IPEM. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22226589     DOI: 10.1016/j.medengphy.2011.12.011

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  8 in total

1.  Compression and Encryption of ECG Signal Using Wavelet and Chaotically Huffman Code in Telemedicine Application.

Authors:  Mahsa Raeiatibanadkooki; Saeed Rahati Quchani; MohammadMahdi KhalilZade; Kambiz Bahaadinbeigy
Journal:  J Med Syst       Date:  2016-01-16       Impact factor: 4.460

2.  Adaptive empirical pattern transformation (ADEPT) with application to walking stride segmentation.

Authors:  Marta Karas; Marcin Stra Czkiewicz; William Fadel; Jaroslaw Harezlak; Ciprian M Crainiceanu; Jacek K Urbanek
Journal:  Biostatistics       Date:  2021-04-10       Impact factor: 5.899

3.  Analysis of QRS-T subtraction in unipolar atrial fibrillation electrograms.

Authors:  J L Salinet; J P V Madeiro; P C Cortez; P J Stafford; G André Ng; G André Ng; F S Schlindwein
Journal:  Med Biol Eng Comput       Date:  2013-04-07       Impact factor: 2.602

4.  Electrocardiogram Delineation in a Wistar Rat Experimental Model.

Authors:  Pedro David Arini; Sergio Liberczuk; Javier Gustavo Mendieta; Martín Santa María; Guillermo Claudio Bertrán
Journal:  Comput Math Methods Med       Date:  2018-02-08       Impact factor: 2.238

5.  A QRS Detection and R Point Recognition Method for Wearable Single-Lead ECG Devices.

Authors:  Chieh-Li Chen; Chun-Te Chuang
Journal:  Sensors (Basel)       Date:  2017-08-26       Impact factor: 3.576

6.  An Improved Sliding Window Area Method for T Wave Detection.

Authors:  Haixia Shang; Shoushui Wei; Feifei Liu; Dingwen Wei; Lei Chen; Chengyu Liu
Journal:  Comput Math Methods Med       Date:  2019-04-01       Impact factor: 2.238

7.  A Real Time QRS Detection Algorithm Based on ET and PD Controlled Threshold Strategy.

Authors:  Aiyun Chen; Yidan Zhang; Mengxin Zhang; Wenhan Liu; Sheng Chang; Hao Wang; Jin He; Qijun Huang
Journal:  Sensors (Basel)       Date:  2020-07-18       Impact factor: 3.576

8.  Automatic QRS complex detection using two-level convolutional neural network.

Authors:  Yande Xiang; Zhitao Lin; Jianyi Meng
Journal:  Biomed Eng Online       Date:  2018-01-29       Impact factor: 2.819

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.