Literature DB >> 22226411

Highly sensitive electrochemical detection of potential cytotoxicity of CdSe/ZnS quantum dots using neural cell chip.

Tae-Hyung Kim1, Waleed Ahmed El-Said, Jeong-Woo Choi.   

Abstract

Cell chip was recently developed as a simple and highly sensitive tool for the toxicity assessment of various kinds of chemicals or nano-materials. Here, we report newly discovered potential cytotoxic effects of CdSe/ZnS quantum dots (QDs) on intracellular redox environment of neural cancer cells at very low concentrations which can be only detected by cell chip technology. Green (2.1 nm in diameter) and red (6.3 nm in diameter) QDs capped with cysteamine (CA) or thioglycolic acid (TA) were found to be toxic at 100 μg/mL when assessed by trypan blue and differential pulse voltammetry (DPV). However, in case of concentration-dependent cytotoxicity, toxic effects of TA-capped QDs on human neural cells were only measured by DPV method when conventional MTT assay did not show toxicity of TA-capped QDs at low concentrations (1-10 μg/mL). Red-TA QDs and Green-TA QDs were found to decrease electrochemical signals from cells at 10 μg/mL and 5 μg/mL, respectively, while cell viability decreased at 100 μg/mL and 50 μg/mL when assessed by MTT assay, respectively. The relative decreases of cell viability determined by MTT assay were 15% and 11.9% when cells were treated with 5-50 μg/mL of Red-TA QDs and 5-30 μg/mL of Green-TA QDs, respectively. However, DPV signals decreased 37.5% and 39.2% at the same concentration range, respectively. This means that redox environment of cells is more sensitive than other components and can be easily affected by CdSe/ZnS QDs even at low concentrations. Thus, our proposed neural cell chip can be applied to detect potential cytotoxicity of various kinds of molecular imaging agents simply and accurately.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22226411     DOI: 10.1016/j.bios.2011.12.035

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  5 in total

1.  Meta-analysis of cellular toxicity for cadmium-containing quantum dots.

Authors:  Eunkeu Oh; Rong Liu; Andre Nel; Kelly Boeneman Gemill; Muhammad Bilal; Yoram Cohen; Igor L Medintz
Journal:  Nat Nanotechnol       Date:  2016-02-29       Impact factor: 39.213

2.  3D graphene oxide-encapsulated gold nanoparticles to detect neural stem cell differentiation.

Authors:  Tae-Hyung Kim; Ki-Bum Lee; Jeong-Woo Choi
Journal:  Biomaterials       Date:  2013-08-12       Impact factor: 12.479

Review 3.  Neural Cell Chip Based Electrochemical Detection of Nanotoxicity.

Authors:  Md Abdul Kafi; Hyeon-Yeol Cho; Jeong Woo Choi
Journal:  Nanomaterials (Basel)       Date:  2015-07-02       Impact factor: 5.076

4.  Sensitive Bioanalysis Based on in-Situ Droplet Anodic Stripping Voltammetric Detection of CdS Quantum Dots Label after Enhanced Cathodic Preconcentration.

Authors:  Xiaoli Qin; Linchun Wang; Qingji Xie
Journal:  Sensors (Basel)       Date:  2016-08-23       Impact factor: 3.576

Review 5.  Nanostructured surfaces for analysis of anticancer drug and cell diagnosis based on electrochemical and SERS tools.

Authors:  Waleed A El-Said; Jinho Yoon; Jeong-Woo Choi
Journal:  Nano Converg       Date:  2018-04-24
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.